background image

 

12 

Approval 

 

D141479: 785-811 MHz for use in:  

Australia, Czech Republic, France, Germany, Greece, Hungary,  

 

 

 

 

 

Italy, Luxemburg, Netherlands, Norway, Poland, Portugal,    

 

 

 

 

 

Romania, Slovakia, Sweden, Switzerland, Turkey, United Kingdom. 

D141482: 822 – 846 MHz for use in:  

France, Germany, Hungary, Italy, Netherlands, Romania, Sweden,  

 

 

 

 

 

Switzerland, And United Kingdom.  

 

Exclusion of liability 

The frequency tables in this publication are made according to national laws and regulations. The 
frequencies are checked on a regular basis. We don’t take any responsibility for eventual discrepancies 
between our listed frequencies and the frequencies actually approved in a given country. We strongly 
suggest you to inform in your own country or region for any changes or adaptions regarding the allowed 
frequencies. 
 
Please refer to your authority as listed below: 
 

Telecoms & Postal Regulatory Authorities in Europe 

Austria Rundfunk und Telekom Regulierungs-GmbH    

 

 

www.rtr.at 

Belgium Belgian Institute of postal services and telecommunications (BIPT)  www.bipt.be 
Czech Republic Czech Telecommunication Office   

 

 

www.ctu.cz 

Denmark National Telecom Agency   

 

 

 

 

www.tst.dk 

Finnland Finnish Communications Regulatory Authority (FICORA)    

www.ficora.fi 

France Autorité de Régulation des Télécommunications (ART)  

 

www.art-telecom.fr 

Germany Die Bundesnetzagentur

ie B

  

 

 

 

 

www.regtp.de 

Greece National Telecommunications Commission (EET)    

 

www.eett.gr 

Hungary Communication Authority (HIF) 

 

 

 

 

 www.hif.hu 

Iceland Post and Telecom Administration (PTA)  

 

 

 

www.pta.is 

Ireland Commission for Communications Regulation (ComReg)  

 

www.comreg.ie 

Italy Italian Communications Authority (AGC)  

 

 

 

www.agcom.it 

Latvia Telecommunication State Inspection    

 

 

 

www.vei.lv 

Liechtenstein Office for Communications (AK) 

 

 

 

www.ak.li 

Lithuania Radio Administration  

 

 

 

 

 

www.rrt.lt 

Luxembourg Institut Luxembourgeois des Télécommunications (ILT)   

www.etat.lu/ILT 

Netherlands Onafhankelijke Post en Telecommunicatie Autoriteit (OPTA)   www.opta.nl 
Agentschap Telecom   

 

 

 

 

 

 

www.agentschap-telecom.nl 

Ministry of Economic Affairs    

 

 

 

 

 

www.ez.nl 

Norway Norwegian Post and Telecommunications Authority (NPT)    

www.npt.no 

Poland Urzad Regulacji Telekomunikacji (URT)  

 

 

 

www.urt.gov.pl 

Portugal Autoridad Nacional De Comunicaçòes (ICP-Anacom)  

 

www.anacom.pt 

Slovenia Agencija za telekomunikacije, radiodifuzijo in pošto  

 

www.atrp.si

Содержание COM-54

Страница 1: ...COM 54 ORDERCODE D141479 785 811Mhz ORDERCODE D141482 822 846MHz...

Страница 2: ...manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant dap audio...

Страница 3: ...Description Features Overview Frontside Backside Installation Set Up and Operation Set Up Menu Options Volume Set Menu Sensitivity Adjustment Menu SQUELCH Signal Channel solution Menu Frequency Set Me...

Страница 4: ...dequate packaging is the customer s responsibility Highlite reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a...

Страница 5: ...ce Do not insert objects into air vents Do not connect this device to a dimmerpack Do not switch the system on and off in short intervals as this would reduce the system s life Do not drive the inputs...

Страница 6: ...e a qualified engineer inspect for safety before operating If the system has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising conden...

Страница 7: ...141479 822 846 MHz ordernr D141482 4 channel wireless microphone system True diversity receiver Included 4 dynamic hand held microphones 32MHz Phase locked loop PLL circuit technology LCD display Easy...

Страница 8: ...all packing materials from the Com 54 Check that all foam and plastic padding is removed Put the 2 antennas into socket A and B at the backside in a vertical angle Remove the rubber protection caps a...

Страница 9: ...SQUELCH 0 40 dB in 5 dB steps 2 DISPLAY FREQU CHANNL 3 TUNE 785 100 811 000 in steps of 0 025 Hz 4 LOCK LOC OFF LOC ON Sensitivity Adjustment Menu SQUELCH Scroll through the menu by using the SET but...

Страница 10: ...he previous setup When you press UP DOWN the LCD indicates 2 modes either Channel or Frequency If you select channel CHANNL is shown as numerical value If you select FREQU it is shown as actual workin...

Страница 11: ...ton you can change the original state from LOC OFF to LOC ON the LCD will flash Press SET to store the setting the device is locked After storing pressing SET the LCD will stop flashing LOCK ON to LOC...

Страница 12: ...10dB 2 DISPL Choose between FREQU CHANNL TUNE 3 LOC Choose between LOC ON LOC OFF You can change your settings by pressing the UP DOWN buttons Be sure to store your desired setting by pressing the SET...

Страница 13: ...the batteries are fully charged the indicator Led will be GREEN When the LED flashes there is an error Remove the microphone for a moment from the charger and then place it back again 1 Charge LED RE...

Страница 14: ...Telecommunication Office www ctu cz Denmark National Telecom Agency www tst dk Finnland Finnish Communications Regulatory Authority FICORA www ficora fi France Autorit de R gulation des T l communicat...

Страница 15: ...y that the product product COM 54 4Ch Wireless Mic785 811 model number D141479 to which this declaration relates in conformity with the following European harmonised and published standards at date of...

Страница 16: ...y that the product product COM 54 4Ch Wireless Mic822 846 model number D141482 to which this declaration relates in conformity with the following European harmonised and published standards at date of...

Страница 17: ...always to your advantage Periodically check that your cables are in good condition that they are correctly wired and that all their contacts are perfectly efficient a great number of problems faulty...

Страница 18: ...ly dry before linking equipment or supplying electric power Troubleshooting DAP Audio COM 54 This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps b...

Страница 19: ...ent range 12 32dB S N Ratio 80dB Sensitivity 107dBM Stray control 75dB Output level balanced output 0 32dB Power 12 16V DC adapter included Current draw 300mA Dimensions 19 x 245mm X 1U LxWxH Weight 2...

Страница 20: ...2008 DapAudio...

Отзывы: