It's necessary to install an electrical heating belt if water can't drain out in cold weather even the big drain hole has opened.
It is suggested to site the unit with the base electric heater.
5.1.2 Installation requirements
•
Check the strength and level of the
installation ground so that the unit may
not cause any vibrations or noise
during the operation.
•
In accordance with the foundation
drawing in the figure, fix the unit
securely by foundation bolts. (Prepare
six sets each of Φ10 Expansion bolts,
nuts and washers which are readily
available in the market.)
•
Screw in the foundation bolts until their
length is 20mm from the foundation
surface.
CAUTION
Φ10 Expansion
bolt
Rubber
shocking
proof mat
Solid ground
or roofing
Concrete
basement
h≥100mm
≥80
Drain hole
5.14 Filling water
During filling, it might not be possible to remove all air in the system. Remaining air will be removed through the automatic air purge valve
during the first operating hours of the system. Topping up the water afterwards might be required.
•
At all times water pressure should remain above 0.3 bar to avoid air entering the circuit.
•
The unit might drain-off too much water through the pressure relief valve.
• Water quality should be complied with EN 98/83 EC Directives.
NOTE
•
Connect the water supply to the filling valve and open the valve.
• Make sure all the automatic air purge valve are opened (1.5-2 tur
ns).
•
Remove air in the circuit as much as possible using the automatic air purge valve.
Do not fasten the black plastic cover on the
automatic air purge valve at the topside of the unit
when the system is running.Open the automatic
air purge valve, turn it counterclockwise for 1.5-2
turns to release air from the system.
Drain ID:
Φ12
OD:
Φ17
≥100
Drainage pipe
(
purchase
)
5.1.3 Drainage kit installation
ODU drainage kit installation
Fasten the drain kit(accessories) to the hole on the bottom tray as shown in the picture;
If a drain pipe is required, connect the drain pipe to the drain kit as shown in the picture,
and guide the condensed water and defrosting water to a suitable place.
Notice:
1.If necessar
y, please contact the after-sales service to purchase the ODU drain pipe.
2.Heat&cool unit need to drain the condensed water from ODU.Only cooling units needn't.
•
3.In wet and cold areas in winter, the drained water is easy to freeze, which may damage
the fan. Therefore, it is recommended not to install a drain kit, otherwise it is not good for
drainage and protection of the machine.