37
1007332 ISSUE 1
MODEL
UNITS
HPP-i 18
HPP-i 24
HPP-i 30
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%
Heating capacity
kW
21.0
27.5
36.0
COP range
14.8-6.4
15.0-6.8
14.8-6.0
Average COP at 50% Speed
10.3
10.3
10.2
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity
kW
14.5
18.0
23.9
COP range
7.1-4.6
7.5-4.6
7.5-4.6
Average COP at 50% Speed
6.3
6.3
6.3
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity
kW
9.5
11.9
16.0
TECHNICAL SPECIFICATIONS
Operating air temperature
°C
-10°C to 43°C
Water heat temperature set range
°C
18°C to 40°C
Water cool temperature set range
°C
12°C to 30°C
POWER SUPPLY
400V Three Phase 50Hz
Rated input power
kW
0.41-3.15
0.48-3.91
0.64-5.20
Rated input current
A
0.59-4.56
0.69-5.66
0.92-7.53
Maximum input current
A
5.8
7
9.5
Rated RCD type B
mA
30
30
30
Rated Fuse aM / MCB type C
A
10
10
16
Sound pressure level at 10m
dB(A)
20.4-33.7
23.0-34.4
22.1-34.2
Recommended water flow rate
m
3
/h
8.0-10.0
10.0-12.0
12.0-18.0
Pressure drop
m/kPa
0.61/6.0
0.77/7.5
0.85/8.5
Pool water connections
Inches
1½” or 50mm Female
GENERAL DATA
Net dimensions (w x d x h)
mm
954x429x755
1084x429x948
1154x539x948
Packed dimensions (w x d x h)
mm
1040x445x655
1130x445x985
1200x555x985
Net weight
kg
68
93
120
HERMETIC SYSYEM
Refrigerant charge R32
kg
1.2
2.0
2.7
Minimum area requirement
m2
12.3
34.0
62.0
NOTES: Heat pump performance parameters are subject to change without notice. Always refer to the
nameplate. Global warming potential (GWP) R32 - 675.
The data is subject to modification without prior warning.