36
1007332 ISSUE 1
OWNER/INSTALLATION MANUAL
8�0 DATASHEETS
MODEL
UNITS
HPP-i 8
HPP-i 12
HPP-i 16
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%
Heating capacity
kW
9.5
13.0
20.0
COP range
13.2-5.4
13.5-5.6
13.5-5.7
Average COP at 50% Speed
8.9
9.7
9.3
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity
kW
7.0
9.5
13.5
COP range
6.9-4.2
7.0-4.0
7.0-4.2
Average COP at 50% Speed
6.3
6.1
6.3
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity (kW)
3.9
5.2
7.4
TECHNICAL SPECIFICATIONS
Operating air temperature
°C
-5°C to 43°C
Water heat temperature set range
°C
18°C to 40°C
Water cool temperature set range
°C
12°C to 30°C
POWER SUPPLY
230V Single Phase 50Hz
Rated input power
kW
0.3-1.79
0.40-2.38
0.57-3.21
Rated input current
A
1.38-7.58
1.82-10.8
2.60-14.61
Maximum input current
A
9.5
12.5
19.5
Rated RCD type F
mA
30
30
30
Rated Fuse aM / MCB type C
A
16
16
25
Sound pressure level at 10m
dB(A)
19.6-31.5
21.9-32.0
24.3-36.1
Recommended water flow rate
m
3
/h
3.0-5.0
4.0-6.0
7.0-10.0
Pressure drop
m/kPa
0.36/3.5
0.41/4.0
0.56/5.5
Pool water connections
Inches
1½” or 50mm Female
GENERAL DATA
Net dimensions (w x d x h)
mm
864 x 359 x 648 864 x 359 x 648 954 x 359 x 748
Packed dimensions (w x d x h)
mm
950 x 375 x 675 950 x 375 x 675 1040 x 375 x 775
Net weight
kg
47
49
68
HERMETIC SYSTEM
Refrigerant charge R32
kg
0.6
0.9
1.1
Minimum area requirement
m2
3.1
6.9
10.3
NOTES: Heat pump performance parameters are subject to change without notice. Always refer to the
nameplate. Global warming potential (GWP) R32 - 675.
The data is subject to modification without prior warning.