12
1007332 ISSUE 1
OWNER/INSTALLATION MANUAL
> 50 cm
Plant room
Heat Pump*
Wall
Heat Pump
Possible positions of HPP-i Heat Pump
Wall
Suitable opening
Heat Pump*
>70 cm
Heat Pump
>70 cm
>250 cm
Heat Pump
The red lines represent the air inlet area
* Controls are obscured by the wall� Connect to
optional remote control panel or Wi-Fi before
installing the heat pump in position�
Required free areas to provide air flow to and from heat
pumps when installed in an enclosed area or where
required to pass air through a wall etc. Ensure the heat
pump is sealed against the wall so the outlet air cannot
recirculate. Ensure the hole through the wall is sealed
to avoid the outlet air entering cavities and is smooth
so the outlet air is not restricted.
Free area is the available area through which air can
pass through a grille or louvres.
Minimum free areas m
2
Model
Discharge area
HPP-i 8
0.169
HPP-i 12
0.169
HPP-i 16
0.169
HPP-i 18
0.229
HPP-i 24
0.301
HPP-i 30
0.301