Oilbuner

Type Gulliver RG3

GB

Technical instructions

Main components of the oilburner,

dimensions

Type

393 T1

Terminal power – output

87,4 – 188,4 kW (H

i

)  (7 – 15 kg /h)

Fuel

Viscosity max. 6 mm

2

/s (1,5° E) at 20° C

Electrical supply

230 V +10% -15% 50 Hz

Electrical consumption

380 W

Capasitor

6,3 µF

Ignition transformer

Secondary: 8 kV 16 mA

Control box

550 SMD

Pump capacity

Max. 30 kg/h at 10 bar

Pump pressure

8 – 15 bar

Approval

MK 10.10/1255

1. Oil pump
2. Control box
3. Reset button
4. Boiler flange
5. Air-damper
6. Flange for nozzle holder
7. Photo resistance

K:\framen\instrukt\Dantherm\RG\Engelsk\RG3\RG3.fm-T1-021108-dm/lbk

Dimensions:

Main components of the oilburner:

228

142

Ø123

285

12

36

300

345

213

127

99

99

11

160

190

45˚

45˚

(All measurements are in mm)

Содержание Gulliver RG3

Страница 1: ...Oilburner RG3 GB Code No 970929...

Страница 2: ...instruction should be kept in the furnace room The user is responsible for the burners working order and that the following points are observed Regulations The furnace room and the room containing th...

Страница 3: ...W Capasitor 6 3 F Ignition transformer Secondary 8 kV 16 mA Control box 550 SMD Pump capacity Max 30 kg h at 10 bar Pump pressure 8 15 bar Approval MK 10 10 1255 1 Oil pump 2 Control box 3 Reset butto...

Страница 4: ...on chamber Po Technical instructions Capacity diagram start up cycle K framen instrukt Dantherm RG Engelsk RG3 RG3 fm T2 021108 DM lbk Burner start up cycle Thermostat Motor Ignition transformer Valve...

Страница 5: ...he by pass screw 3 and then screw again the plug 2 It is sufficient to loosen the suction gauge con nection 5 and wait until oil flows out It is neccesary to install a filter on the fuel sup ply line...

Страница 6: ...on the oil supply pipes position to the right or to the left hand side of the burner One line system On the tank installa tion where vacuum can occur in the oil tubes you install a flow control betwee...

Страница 7: ...to the arrow direction after removing all components the 7 pin plug and earth wire Ignition transformator The ignition transformator is build in in the control box The ignition cables are con nected t...

Страница 8: ...ozzle holder 2 and lock it by screw 3 For prospective adjustments of the eletro des assembly loosen screw 4 Combustion head setting It depends on the output of the burner and is carried out by rotatin...

Страница 9: ...ended Delavan Type W B Danfoss Type S B Monarch Type R Steinen Type S Q K framen instrukt Dantherm RG Engelsk RG3 RG3 fm I2 021108 dm lbk Adjustment Nozzle Pump pressure Burner output Combustion head...

Страница 10: ...Oilburner Type Gulliver RG3 Page 8 of 9 Electrical wiring K framen instrukt Dantherm RG Engelsk RG3 RG3 fm E1 021108 dm lbk...

Страница 11: ...ver 11 80007458 Viewing port 12 80007644 Bracket and screw 13 80000443 Joint 14 80007465 High voltage lead 15 80007651 Suction duct 16 80007466 Support 17 80007645 Diffuser disc 18 80007495 Electrode...

Отзывы: