Dantherm CDF 35 Скачать руководство пользователя страница 21

 

67 

975682 

 Ve

rs

io

2

.3

 • 

0

3

.0

4

.2

0

1

4

  

 
 
 
 
 

 

Contact Dantherm 

 
 

Dantherm Air Handling A/S 
Marienlystvej 65 
7800 Skive 
Denmark 
 
 
Phone +45 96 14 37 00 
Fax  +45 96 14 38 00 
 
[email protected] 
www.dantherm.com 

Dantherm Air Handling AS 
Postboks 4 
3101 Tønsberg 
Norway 
Besøksadresse: Skallestad, Nøtterøy 
 
Phone +47 33 35 16 00 
Fax  +47 33 38 51 91 
 
[email protected] 
www.dantherm.no 

Dantherm Air Handling AB 
Virkesgatan 5 
614 31 Söderköping 
Sweden 
 
 
Phone +(0) 121 130 40 
Fax  +(0) 121 133 70 
 
[email protected] 
www.dantherm.se 

Dantherm Air Handling (Suzhou) Ltd. 
Bldg#9, No.855 Zhu Jiang Rd.,  
Suzhou New District, Jiangsu 
215219 Suzhou 
China 
 
Phone +86 512 6667 8500 
Fax  +86 512 6667 8500 
 
[email protected] 
www.dantherm-air-handling.com.cn 

Dantherm Limited 
12 Windmill Business Park 
Windmill Road, Clevedon 
North Somerset, BS21 6SR 
England 
 
Phone +44 (0)1275 87 68 51 
Fax  +44 (0)1275 34 30 86 
 
[email protected] 
www.dantherm.co.uk 

Dantherm Air Handling Inc. 
110 Corporate Drive, Suite K 
Spartanburg, SC 29303 
USA 
 
 
Phone +1 (864) 595 9800 
Fax  +1 (864) 595 9810 
 
[email protected] 
www.dantherm.com 

  

Содержание CDF 35

Страница 1: ...1 975682 Version 2 3 03 04 2014 CDF 35 45 Service manual Rev 2 3 en...

Страница 2: ...manual covers the following main topics Topic See page General information 14 Product and functional description 15 Mounting and installation guide 18 Service guide 19 Fault finding guide 20 Technical...

Страница 3: ...ormity Dantherm A S Marienlystvej 65 DK 7800 Skive hereby declare that the unit mentioned below Dehumidifier model CDF 35 45 product no covered by this declaration is in conformity with the following...

Страница 4: ...ing energy of the compressor be ing turned into heat energy more heat is returned to the air than was previously ex tracted This extra heat corresponds to an approximate increase in temperature of 5 C...

Страница 5: ...has been switched off on the main switch by the built in hygrostat or by an external hygrostat it will take 30 seconds before the unit can be switched on again This is a safety function protecting the...

Страница 6: ...ctive demand controlled defrosting is incorporated into the electronic control The evaporator coil is defrosted by means of hot refrigerant bypassing the condenser and being fed through the evaporator...

Страница 7: ...t The condensate outlet is located at the bottom of the dehumidifier The unit has a drain spigot intended for connection of a flexible or fixed water connection If water drain through the wall is chos...

Страница 8: ...icular maintenance Cleaning of the dehumidifier CDF 35 45 CDF 35T 45T The air inlet filter has to be checked once a month and cleaned if necessary Re move the front cover panel of the unit and take ou...

Страница 9: ...ser coil is dirty Check if the room temperature is higher than 30 C If the room tem perature is higher than 30 C the unit must be stopped Check that the front cover panel CDF duct openings CDF T are n...

Страница 10: ...y V Hz 230 50 Max ampere consumption A 3 0 5 3 Max power consumption kW 0 70 1 2 Air volume at max external pressure m3 h 250 500 Refrigerant R407C Quantity of refrigerant kg 0 6 0 950 GWP Global Warm...

Страница 11: ...entive maintenance Dantherm A S offers to do the preventive maintenance on the units so that they at all times will operate according to factory standards Corrective and emergency repair In case of ma...

Страница 12: ...er receiver liquid line drier Receiver Trockenfilter Magnetventil til trykudligning solenoid valve for pres sure equalization Magnetventil f r Druckausgleich Ventilator fan Ventilator Kontra ventil No...

Страница 13: ...54 Eldiagram Wiring diagram Schaltplan Sch ma lectrique Schema elettrico CDF 35 35T Diagram CDF 35 35T 1 x 230 V 50 Hz...

Страница 14: ...55 975682 Version 2 3 03 04 2014 Eldiagram Wiring diagram Schaltplan Sch ma lectrique Schema elettrico CDF 45 45T Diagram CDF 45 45T 1 x 230 V 50 Hz...

Страница 15: ...mperf ler Evaporator sensor Verdampfer f hler Sonde d vaporateur Sensore dell evaporato re HYG Indbygget hygrostat Built in hygrostat Eingabauter Hygrostat Hygrostat incorpor Umidostato interno M2 Ven...

Страница 16: ...odel A B CDF 35T 387 mm 887 mm 130 x 410 mm CDF 45T 692 mm 1192 mm 130 x 720 mm Kanal bning i muren Duct opening in the wall Kanal ffnung im Mauer Ouverture de gaine dans le mur Apertura nel muro per...

Страница 17: ...A M lene angiver placeringen af v gbeslaget EN The dimensions indicate the placing of the suspension bar DE Die Dimensionen zeigen die Plazierung der Wandkonsole an FR Les dimensions indiquent la posi...

Страница 18: ...2 3 03 04 2014 Reservedele Spare parts Ersatzteile Pi ces de rechange Parti di ricambio Illustration CDF 35 45 1 230 V 50 Hz Forts ttes continued overleaf fortsetzt Suite la page suivante continua all...

Страница 19: ...Condenser CDF 45 6 069931 7 293736 Ventilator 1600mm ledning Fan with 1600 mm cable 8 069938 CDF 35 CDF 35 069930 CDF 45 CDF 45 9 293631 CDF 35 CDF 35 293629 CDF 45 CDF 45 10 069928 11 069929 12 6000...

Страница 20: ...til CDF 45 Thermostatic valve CDF 45 25 26 032675 F ler 2600mm Sensor 2600 mm 27 605470 Magnetventil Solenoid valve 28 605440 Spole for magnetventil Coil for solenoid valve 29 604880 Kontraventil CDF...

Страница 21: ...n Phone 0 121 130 40 Fax 0 121 133 70 infose dantherm com www dantherm se Dantherm Air Handling Suzhou Ltd Bldg 9 No 855 Zhu Jiang Rd Suzhou New District Jiangsu 215219 Suzhou China Phone 86 512 6667...

Страница 22: ...68 Dantherm Air Handling A S Marienlystvej 65 7800 Skive Denmark www dantherm com service dantherm com 975682 975682...

Отзывы: