HEAT PUMPS FOR POOLS. SPECIALIST APPLICATIONS - CHILLERS, HEATERS AND HEATER CHILLERS
DATASHEETS
Model
Units
AW634AHC WA634ACH/ACL
WA1222AC/
WA1234BC
AW1234BHC AW1834BHC
Performance
Water heating mode
Ambient 10°C, water 30°C
kW
3.39
n/a
n/a
8.7
12.0
Ambient 30°C, water 30°C
kW
6.6
n/a
n/a
13.0
16.0
Water cooling mode
Ambient 10°C, water 15°C
kW
5.3
5.3
9.0
9.0
11.4
Ambient 45°C, water 15°C
kW
3.4
3.4
7.0
7.0
8.8
Electrical
Total power consumed
Water heating mode
Ambient 10°C, water 30°C
kW
1.31
n/a
n/a
2.0
2.7
Ambient 30°C, water 30°C
kW
1.46
n/a
n/a
2.3
3.1
Water cooling mode
Ambient 10°C, water 15°C
kW
1.5
1.5
1.7
1.7
2.2
Ambient 45°C, water 15°C
kW
1.8
1.8
2.6
2.6
3.5
Min supply capacity (Max F L A) I ph N
A
12
12
23.9
n/a
n/a
Min supply capacity (Max F L A) 3 ph N
A
n/a
n/a
10.5
17.1
9.2
Max supply fuse 1 ph N
A
20
20
35
n/a
n/a
Max supply fuse 3 ph N
A
n/a
n/a
16
25
16
Water flows etc.
Water flow rate
L/minute
33
33
33
33
42
Water pressure drop at rated flow
metres hd
1.4
1.4
7.0
7.0
3.5
Max working pressure water
bar
3.5
3.5
3.5
3.5
3.5
Water connections
inches
3/4 BSPM
1.5” BSPM
Condensate drain connections
inches
3/4 domestic waste
1.5” BSPM
Compressor
Nominal power consumed
kW
1.4
1.4
3.4
3.4
3.2
LRA- 1phN
A
42
42
100
N/A
N/A
RLA- 1phN
A
9
9
16.6
N/A
N/A
Soft start amps 1 ph N
A
23
23
34
N/A
N/A
LRA- 3phN
A
n/a
n/a
48
48
48
RLA.-3phN
A
n/a
n/a
7.3
7.9
10
Soft start amps 3 ph N
A
n/a
n/a
17
25
25
Main fan
Air flow Anemometer ~ air on grille, dry evaporator
m³/h
2400
2400
3200
3200
4300
Max external static pressure
mmWg
0
0
0
0
4
FLA- 1ph N
A
2.2
2.2
3.8
3.8
N/A
FLA- 3ph N
A
N/A
N/A
N/A
N/A
1.65
Physical dimensions
Width un-packed
mm
820
820
1060
1060
980
Depth un-packed
mm
702
702
705
705
700
Height un packed
mm
762
762
807
807
1490
Weight un-packed
kg
111
111
150
157
230
Sound pressure levels at 3 metres
dbA
63
63
71
71
61
For Accurate Application Sizing Consult Dantherm Ltd
1mm WG = 9.8 Pa
NOTES
1) Weight and dimensions nett
1mm WG = 9.8 Pa
2) Performance design limitations
1m hd =1.4 psi
Water heating mode:
Ambient = 10°C min 50°C max. Note: WA634ACL 0ºC min 35ºC max
1L/min = 0.22 gall/min
Water = 10°C min 50°C max
Water cooling mode:
Ambient = 10°C min 50°C max. Note: WA1222AC 10ºC min 40ºC max
Water = 10°C min 35°C max
3) Pool water to have correct balance, pH 7.2 - 7.8. Free Chlorine 1.0 - 2.0 ppm domestic, 3.0 - 6.0 commercial.
4) Allow 500mm clearance to service panels
5) Dantherm Ltd. reserves the right to change or modify models without prior notice
6) Global warming potential (GWP) R407c 1774, R134a 1430
39
SD331852 ISSUE 7
Содержание calorex PP22BC
Страница 2: ...2 SD331852 ISSUE 7 OWNER INSTALLATION MANUAL 634ACH ACL AHC 1222AC 1234BC BHC 1834BHC PP22BC...
Страница 50: ...Page 50 SD331852 issue 5...