Dantel D18-05547 Series Скачать руководство пользователя страница 19

05547-0798 <90-00047>

 P

AGE

 19

INSTALLATION

F

IG

. 17 - 44023 PABX/T

RUNK

 I

NTERFACE

 S

TRAP

 S

ETTINGS

44023-00

PABX/TRUNK

INTERFACE

BUSY

INC CALL

OFF HOOK

TRANSMIT

LINE

DROP

MON

TEST

RST

LINE

DROP

MON

RECEIVE

DIST

DIST

GND

GND

A11-44023-00 REV__

INC CALL LED

OFF HOOK LED

XMT LEVEL

ADJUST

RCV LEVEL

ADJUST

GND

START

LP

CONT

M LEAD

BATTERY

CONF

E CONT

IN

OUT

IN

OUT

IN

OUT

OUT

IN

IN OUT

IN OUT

BUSY LED

M LEAD GROUND

IN

OUT

PRIVACY

BUSY CONTROL

IN

OUT

RCV PAD

IN

OUT

XMT PAD

IN

OUT

R73

R24

R5

Содержание D18-05547 Series

Страница 1: ...dioactive fields For more complete information on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1998 by Dantel Inc Dantel is a registered t...

Страница 2: ...ackage B15 00331 00 DTSS3ON Order Wire PABX Interface Off Net Assembly A18 05723 01 Network Interface Shelf A17 49017 00 Spare components for 41096 A11 44020 00 DTMF Decoder A12 49018 00 Station Selec...

Страница 3: ...andset on the front of the 41096 panel and call someone at a remote terminal The voice circuit uses channel 1 of the system 44214 46105 MASTER CALLED TERMINAL FIBER TERMINAL 44214 00 or Other External...

Страница 4: ...andset and start sending or receiving digital data 4 When you finish press the key to disconnect the modem at the remote terminal Release the channel 2 push button You can ei ther release the channel...

Страница 5: ...ules All options and levels have been factory set 4 Visually inspect the shelf and modules for obvious damage 5 Close the front panel of the assembly 6 Use the ohmmeter to check for a short across the...

Страница 6: ...OUT J5 J6 IN OUT IN OUT CAUTION Do not reverse power SYSTEM REAR VIEW 06 3 2 1 7 C5 U3C6 U5 C4 C3 JP1 R6 R8 J6 1 55 2 56 55 F1 P2 1 6 7 19 1 20 2 J1 S2 12 PORT 2 TERMINATION S3 OUT IN PORT 4 TERMINATI...

Страница 7: ...device will indicate when the fuse has blown When the fuse blows connection 2 will have negative battery on it Wire negative battery 21 to 56 VDC to connection 1 of TB1 5 End of this section FIG 4 EQU...

Страница 8: ...et JP2 JP5 to the 2 3 position to bypass this circuit FIG 5 STRAP LOCATION NOTE All switch strap and level set tings are factory set INSTALLATION J7 IN OUT JP4 JP3 JP2 JP5 JP5 J5 J6 IN OUT IN OUT SYST...

Страница 9: ...ce the CTL LMT A strap in the IN position to prevent the ALL CHAN volume control knob from turning off the speaker Place the strap in the OUT position to allow the volume control knob to turn off the...

Страница 10: ...LK 1 and XMT CLK 2 straps in TERM 2 Set the RCV CLK 1 and RCV CLK 2 straps in TERM 3 Set the RCV DATA 1 and RCV DATA 2 straps in TERM 4 Set the M LEAD 1 and M LEAD 2 straps in YES 5 Set the MODE strap...

Страница 11: ...TERM RPTR NO YES LPBK 1 OFF ON LPBK 2 BRDG CHANNEL 2 CHANNEL 1 M LEAD 2 OFF ON DATA CLK CLK RCV RCV XMT NO NC DATA RCV TM T T TM T T TERM RPTR S101 S2 S1 T T L T E R M RCV DATA T T L T T L T E R M RC...

Страница 12: ...e in the middle slot in the top equipment shelf 6 End of this section NOTE The 44214 communicates with a second 44214 at the other end One of these two modules must have its ORG ANS switch set for ORG...

Страница 13: ...ll this order wire terminal for voice communications 3 On the 49018 subassembly set the station 2 code with S4 S5 and S6 S4 is the first digit Use this code to call this order wire terminal when it is...

Страница 14: ...t of the bottom equipment shelf 3 End of this section FIG 12 44022 STRAP LOCATIONS SIDE TONE IN OUT IN OUT 10dB XMT PRIVACY REMOTE M LEAD OUT IN OUT IN OUT IN ALL GRP RCV PAD OUT IN RG 600 OHM 600 OHM...

Страница 15: ...k the tone levels of the external modem 1 Apply power to the order wire system 2 Push in the CHANNEL 1 and 2 buttons on the front of the 41096 3 Connect a 600 ohm dB meter bridging to the XMT MON jack...

Страница 16: ...ator to the XMT DROP jack on the 44022 module 5 Connect a 600 ohm dB meter bridging to the channel 1 XMT MON jack on the front panel of the 46105 module 6 Adjust the transmit level on the front of the...

Страница 17: ...ve level 1 Connect a 600 ohm load across the output of a signal generator With a 600 dB meter across those same outputs adjust the output level of the generator until the meter reads 29 dBm at 1004 Hz...

Страница 18: ...ION FIG 15 44020 DTMF DECODER STRAP SETTINGS FIG 16 49018 STATION SELECTOR SUBASSEMBLY SWITCH AND STRAP SETTINGS A C CKT 2 X2 X1 X6 12 P1 P2 1 12 S1 S2 S3 S4 S5 S6 IN OUT 1 DIGIT 2 DIGIT 3 DIGIT RESET...

Страница 19: ...OK TRANSMIT LINE DROP MON TEST RST LINE DROP MON RECEIVE DIST DIST GND GND A11 44023 00 REV__ INC CALL LED OFF HOOK LED XMT LEVEL ADJUST RCV LEVEL ADJUST GND START LP CONT M LEAD BATTERY CONF E CONT I...

Страница 20: ...ET SWITCH AND STRAP SETTINGS INSTALLATION A11 44443 00 44443 XX TERM SET RCV ATTEN dB OUT IN OUT IN 4 WIRE LINE XMT RCV 2 WIRE DROP XMT RCV XMT ATTEN dB OUT IN OUT IN 1 8 ON OPEN 600 900 S2 600 900 S1...

Страница 21: ...al Control Optional Control 44023 MODULE Line RCV Level 16 to 3dBm Drop XMT Level 3 to 7dBm Manual Privacy M Lead Dry Contact E Lead CONTROL INTERFACE Loop Start Ground Start No Conferance Delay No Bu...

Страница 22: ...h and Strap Settings Verify that the switches and straps are set as shown in Fig 20 FIG 20 44022 SUBSCRIBER LINE INTERFACE SWITCH AND STRAP SETTINGS Wiring Connect the 05723 Network Interface to the 0...

Страница 23: ...e digit station 1 code of the ter minal you want to call You will hear the ring back tone 4 If the call is not answered you can Press the button to terminate the call Wait 90 seconds for the call to b...

Страница 24: ...ill hear one ring followed by a short tone burst 2 Dial the desired order wire station code The caller will hear a ring back tone until the party answers If a loop trunk is used the person at the answ...

Страница 25: ...S8 register in the modem If the delay is not long enough to get to the off net shelf and onto the PSTN then this value may have to be adjusted The typical setting of a delay is as follows ATS8 n wher...

Страница 26: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...