P
AGE
10
05547-0798 <90-00047>
INSTALLATION
F
IG
. 7 - 41096 P
ANEL
S
TRAP
L
OCATIONS
46105 D
UAL
VF 64-K
ILOBIT
C
HANNEL
M
ODULE
To set the switches:
Refer to Fig. 8 for the locations of the switches.
1.
Set S1 (BRDG) in RPTR.
2.
Set S2 (LPBK 1) in OFF.
3.
S101 (LPBK 2) in OFF.
To set the straps:
Refer to Fig. 8 for the locations of the straps.
1.
Set the XMT CLK 1 and XMT CLK 2 straps in TERM.
2.
Set the RCV CLK 1 and RCV CLK 2 straps in TERM.
3.
Set the RCV DATA 1 and RCV DATA 2 straps in TERM.
4.
Set the M LEAD 1 and M LEAD 2 straps in YES.
5.
Set the MODE strap in RPTR.
6.
Reinstall the module in the left slot in the top equipment shelf.
7.
End of this section.
N
OTE
:
All switch, strap, and level
settings are factory-set.
N
OTE
:
If an external clock is not
used, strap XMT CLK 1
and XMT CLK 2 to TTL+.
N
OTE
:
To strap the module for
terminal mode, set switch
S1 to TERM and place the
MODE strap in TERM.
IN