P
AGE
10
05776-1198 <90-00124>
14.
Read system test-tone level (+7 dBm). Adjust TRANSMIT level
control as required.
NOTE:
Any source device that loads down the input must be
disconnected.
15.
Disconnect the meter and test oscillator.
16.
Connect an A18-05775-00 Speaker/Monitor panel to the Universal
assembly A18-05776-XX by using a 8 wire RJ 45 cable with no
twists in the make-up of the cable. Pin 1 to Pin 1, Pin 2 to Pin 2,
etc. Connect to the RJ 1 connector of the Universal assembly and
the RJ 1 connector of the A18-05775-00.
NOTE:
An alternative to a A18-05775-00 is a regular C13-41096-00
speaker/monitor panel connected to the RJ 1 connector of the
A18-05776-00. The RJ plug would connect as follows:
17.
Select the number one OW by pushing in the number one switch of
the A18-05775-00.
18.
Remove the handset of the A18-05775-00 and the number one LED
on the panel should light.
19.
Replace the handset and the LED should go off.
20.
Remove the handset again and check B-7, Connector C1 Pin 34 and
C2 Pins 11 and 12 for ground.
21.
With the handset off-hook there should be -Battery between
B, Pin 9 and B, Pin 10.
22.
Replace the handset and the ground should be removed from B-7,
C1 Pin 34, and C2 Pins 11 and 12, and the -battery should be re-
moved from B Pin 9.
23.
End of 44022 Alignment Procedure.
ALIGNMENT PROCEDURES
RJ1 CONNECTOR PIN
ON A18-05776-XX
1
2
3
4
5
6
7
8
CONNECTED TO
ORDER WIRE
P1-1
P2-6
P2-4
P2-2
P2-5
P2-1
P2-3
P1-9