The following T/Shell programs, and all earlier versions of these
programs, are copy-protected. Current versions are not copy-
protected. Do not copy any T/Shell program with a version later
than those listed here, into a directory that has T/Shell pro-
grams with these versions or lower.

Status Monitor GPP Editor

A22-46502-XX, Version 2.0

TL1 GPP Editor

B22-46504-XX, Version 2.2

40 MAP Editor

A22-46508-XX, Version 1.3

41 MAP Editor

A22-46512-XX, Version 1.1

X.25 Sync Editor

A22-46513-XX, Version 2.1

X.25 Cascade Editor

A22-46516-XX, Version 1.0

TL1/NMA Converter Editor

A22-46521-XX, Version 1.0

X.25 Cascade Editor

A22-46522-XX, Version 1.0

Status Monitor GPP Loader

A22-46703-XX, Version 1.0

If you do not know the version number of a T/Shell program
that is already installed on your computer, go to the first
screen of the program. Press the F1 (Info) key to display the
version number.

5.

Type COPY A:*.* This assumes that the disk is in drive A. If it is
in a different drive, type the letter of that drive.

6.

Press Enter to copy all the files into your TSHELL directory from
the disk in your diskette drive.

7.

After the software has been copied into the TSHELL directory,
store the disk in a safe place.

STANDARDS

T

his section describes those commands, key, and standards

common to all Dantel software packages.

S

OFTWARE

 S

TANDARDS

H

IGHLIGHT

A highlighted option in a menu is the currently selected option.
To activate an option, do either of the following:

1.

Press Enter if the option is highlighted.

2.

Type the letter of the hot key.  A hot key is a specific key that can
open an option. With a color monitor, a hot key is indicated by a
yellow letter. With a monochrome monitor, a hot key is indicated by
a capital letter. In the Master Menu, the hot keys are the option
numbers. When you use the hot key method, the option does not
have to be highlighted.

INSTALLATION

Содержание 46517-92

Страница 1: ...complete information on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1998 by Dantel Inc Dantel is a registered trademark of Dantel Inc IS...

Страница 2: ...This chapter explains how To install the software program on your computer 1 Turn on the power to the computer and monitor Wait for the DOS Disk Operating System prompt to appear 2 Insert the 46517 s...

Страница 3: ...screen of the program Press the F1 Info key to display the version number 5 Type COPY A This assumes that the disk is in drive A If it is in a different drive type the letter of that drive 6 Press Ent...

Страница 4: ...the first field When editing the first field they exit that window When at a submenu they return cursor to the previous menu When at the Master Menu they exit the program Up Arrow The up arrow usually...

Страница 5: ...left to the previous word Moves the cursor right to the previous word Deletes to the end of the field Calls up the Default Box if there is one DEFAULT BOX When defining certain fields a default box ap...

Страница 6: ...you must select the Quit option from the Master Menu whenever you want to leave the T Shell program NEVER turn off the computer without properly exiting the program Doing so could corrupt the data fi...

Страница 7: ...GPP Parameters Does the following Sets the communications parameters for uploading and downloading T Shell configurations between the 46517 NEC to GPP Editor and the 46062 GPP Specifies where to store...

Страница 8: ...Parameters options LCD Mode If you are using a monochrome monitor or a laptop computer with a monochrome LCD display select YES use LCD mode If you are using a color monitor select NO do not use LCD...

Страница 9: ...synonymous Here is the NEC to GPP Editor screen with the NEC GPP System Menu To select an option 1 Highlight an option For brief descriptions of the options refer to the next section on Menu Overview...

Страница 10: ...and their corresponding alarm points TRANSFER Provides utilities for the following Downloading the configuration to a TL1 GPP database Uploading a configuration from a TL1 GPP database Downloading a...

Страница 11: ...selection fields Below are the instructions for entering a system name SYSTEM NAME A T Shell GPP configuration must have a name If there are existing configurations a default box appears with their na...

Страница 12: ...Wish to add Y N Type Y to add the new name If N is typed you will be prompted for another name 4 The Polling Type field automatically defaults to NEC Level 2A 5 Press Enter WARNING Refer to the Utili...

Страница 13: ...ctly the first time 6 Press Enter EDIT ADDRESS This is the GPP address The default address is 1 To change the address 1 Highlight Edit Address 2 Press Enter 3 Type in the address Acceptable values are...

Страница 14: ...alarm points Refer to TRE Display and Alarm Point Configuration on the next page F3 Blank Deletes the current entry F5 Compress Removes all unreferenced entries from SID AID and COND tables NOTE Comp...

Страница 15: ...type N the screen prompts you for another address 6 Repeat steps 1 5 to configure additional GPP entries 7 When you finish press F8 to save the information TRE DISPLAY AND ALARM POINT CONFIGURATION To...

Страница 16: ...configure additional TRE displays 6 When you finish press F8 to save the information To edit alarm points 1 In the TRE Display field select a TRE display number NOTE If you do not type in the TRE and...

Страница 17: ...for a list of attributes You can type in the attribute or the forward slash key and the LEV code in the attribute list for example type 1 for MJ The default is NA 13 Press Enter 14 Type in the DIRN a...

Страница 18: ...of points F6 Read Reads point definitions of one polling list and copies them into the current polling list When you press F6 the Read Points window pops up To read point definitions 1 Type in the nam...

Страница 19: ...5 the Block Move window pops up To move a block 1 Type in the first point of the block Acceptable values are 1 64 2 Press Enter 3 Type in the last point of the block Acceptable values are 1 64 4 Press...

Страница 20: ...ion block must accommodate the entire source block For example a block from points 1 10 cannot be moved to a block starting at point 60 because the maximum block is 64 6 Press Enter Alt F7 Previous En...

Страница 21: ...2 Check the GPP Configuration address The address is shown in the NEC Editor screen Press F10 to exit the Transfer window and display the full NEC Editor screen The address must be the same as the de...

Страница 22: ...g you that the data you are about to upload will overwrite any data in the configuration in the com puter Type Y and press Enter to continue or press Enter to discon tinue the operation If you are abo...

Страница 23: ...w 2 Press Enter 3 Go to the subsection that explains the option you selected Polling List Without Points Contains an output of all defined polling list entries Polling List With Points Contains an out...

Страница 24: ...you must press any key to continue The computer exits the program and returns to the Master Menu When a file is selected as the destination of a report you are prompted for a DOS file name If no file...

Страница 25: ...lling list entry Y N If you press Y Yes then press Enter points for each polling list print on separate pages N No is the default when you press Enter points print in a continuous stream with a two li...

Страница 26: ...ributes of defined points SID TABLE Here is an example of a report of SID table entries that appears on the screen The SID Table reports all SIDs defined in the selected data path AID TABLE Here is an...

Страница 27: ...entries that appears on the screen The EQPT Table reports all EQTs defined in the selected data path COND TABLE Here is an example of a report of COND table entries that appears on the screen The CON...

Страница 28: ...Files Rebuild rebuilds damaged index files that are out of synchronization with the data file The rebuilding process uses the data file to create a new index file When you select Key Files Rebuild an...

Страница 29: ...But if you copy a configuration from one location to the same location such as to use a configuration as the basis for creating a new one you must rename the configuration 6 Press Enter 7 To start the...

Страница 30: ...me field To change the name type a new one NOTE When copying a configuration from one location to another you do not have to rename the configuration But if you copy a configuration from one location...

Страница 31: ...his command erases all references to the configuration NEC GPP SYSTEM DEFINITION NEC DATA PATH The NEC Data Path option of the NEC Edit Module menu lets you specify the drive and directory path where...

Страница 32: ...If you specify a drive without a path for example A or C the current path of that drive is loaded into the Data Path parameter 2 Press Enter 3 Press F8 to save the new path NEC DATA PATH NEC PARAMETER...

Страница 33: ...rt that your computer does not have the T Shell program locks up when the computer tries to use that port and you must reboot your computer Baud Sets the baud rate for the communications port Accept a...

Страница 34: ...drive and directory that the computer is to use to store any reports that are sent to a file For more information see the Reports section of the NEC GPP System Definition chapter This field defaults...

Страница 35: ...the terminal The data then can be reviewed at a later time F3 Open Capture File O Cap Opens a capture file F4 Close Capture File C Cap Closes a capture file F5 Load Configuration File Ld Cnf Changes t...

Страница 36: ...The Edit Configuration window appears Options include Change the terminal s configuration for communicating with another device See Terminal Attributes in this section Program the function keys See Sh...

Страница 37: ...press F8 to return to the Edit Configuration window At the last field Prot base press Enter after making a change to the terminal attributes If you do not change the value of the protocol base press...

Страница 38: ...he terminal emulator communicates Acceptable values are Y es echo results in half duplex opera tion and N o don t echo results in full duplex operation This field defaults to N Append LF Tells the com...

Страница 39: ...appears 2 Enter a string of characters up to a maximum of 56 characters An Enter can be included as part of the string by entering Ctrl M 3 Press Enter Press Enter to skip one function key and move to...

Страница 40: ...ars 2 Enter a string of characters up to a maximum of 56 characters An Enter can be included as part of the string by entering Ctrl M 3 Press Enter Press Enter to skip one function key and move to the...

Страница 41: ...s 2 Enter a string of characters up to a maximum of 56 characters An Enter can be included as part of the string by entering Ctrl M 3 Press Enter Press Enter to skip one function key and move to the n...

Страница 42: ...er The new settings are now the defaults for the terminal configu ration whenever the Terminal Emulator is entered from the Master Menu To create a file that does not change the default settings 1 Mak...

Страница 43: ...capture save the data and close the file press F4 The maximum amount of data that can be stored in one capture file is 16 kilobytes This is the contents of approximately eight screens When the file is...

Страница 44: ...line at the bottom of the screen The message in the status line indicates the name of file being transferred and the number of bytes transferred so far To terminate the file transmission press either...

Страница 45: ...o Send EOF Char Z This parameter controls whether the computer transmits an end of file Ctrl Z character at the end of a DOS file Acceptable responses are Y yes or N no The Send EOF Char defaults to N...

Страница 46: ...ten instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respe...

Отзывы: