Dantel 46034 Скачать руководство пользователя страница 18

P

AGE

 18

18 P

AGES

46034-0997 <90-00030>

L

IMITED

 W

ARRANTY

The Seller warrants that the standard hardware products sold will be free from defects in material and

workmanship and perform to the Seller’s applicable published specifications for a period of 18 months for

hardware, and 3 months for software, from the date of the original invoice. The liability of the Seller hereunder

shall be limited to replacing or repairing, at its option, any defective products which are returned F.O.B. to the

Seller’s plant, (or, at the Seller’s option, refunding the purchase price of such products). In no case are products

to be returned without first obtaining permission and a customer return authorization number from the Seller.

In no event shall the Seller be liable for any consequential or incidental damages.
Equipment or parts which have been subject to abuse, misuse, accident, alteration, neglect, unauthorized

repair or installation are not covered by warranty. The Seller shall make the final determination as to the

existence and cause of any alleged defect. No warranty is made with respect to custom equipment or products

produced to the Buyer’s specifications except as specifically stated in writing by the Seller in the contract for

such custom equipment.
This warranty is the only warranty made by the Seller with respect to the goods delivered hereunder, and may

be modified or amended only by a written instrument signed by a duly authorized officer of the Seller and

accepted by the Buyer.
Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the

respective manufacturer. THE SELLER MAKES NO OTHER WARRANTY OF ANY KIND WHATSOEVER,

EXPRESSED OR IMPLIED; AND ALL IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PUR-

POSE WHICH EXCEEDS THE AFORESAID OBLIGATIONS IS HEREBY DISCLAIMED BY THE SELLER.

I

N

 C

ASE

 

OF

 D

IFFICULTY

If you experience difficulty with this equipment, check the following, as appropriate:

1. Switch settings

2. Signal levels

3. Software configuration

4. Connections between Dantel’s equipment and your equipment.

If there is still a problem, substitute equipment that is known to be good. For additional assistance, call

Dantel’s Technical Field Service Department weekdays, 6 

A

.

M

. to 5 

P

.

M

. pacific time:

1-800-4DANTEL (1-800-432-6835).

If a thorough checkout shows a piece of equipment has malfunctioned, you may return it to the factory. For

repairs and emergency replacements, obtain a Return Material Authorization (RMA) number from the Cus-

tomer Service Representative at 

1-800-4DANTEL

 (1-800-432-6835).

To ensure expedient processing of your order, provide a purchase order number and shipping and billing

information when requesting an RMA number. Also, when the units are returned to Dantel, include a descrip-

tion of the failure symptoms for each unit returned. Send defective equipment to:

Dantel, Inc.

2991 North Argyle Avenue

Fresno, California 93727-1388

P.O. Box 55013 • Fresno, CA 93747-5013

Phone (209) 292-1111

Fax (209) 292-9355

http://www.dantel.com

WARRANTY

Содержание 46034

Страница 1: ...recautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1997 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in the U S A INSTALLATION OPERA...

Страница 2: ...e operating with a 49029 RS 232 Current Loop Interface Subassembly The module comes with a TTL subassembly bypass card that allows port nine to function as a TTL data bus interface in the absence of a...

Страница 3: ...s the front panel TX LED The ninth data port provides a mounting for installing various communication subassemblies With the five six lever DIP switches the port supports the following interfaces TTL...

Страница 4: ...S 422 Output Data Port 5 VDC TDX 5 VDC TX CA RX RX CF 54 53 36 56 55 18 RXD TXD CTS RTS DCD DTR DSR 1 2 Strap D Strap C 2 5 VDC 12 VDC 12 VDC RXD TXD CTS RTS DCD 39 41 43 42 40 21 to 56 VDC 35 17 TTL...

Страница 5: ...22 TX Pin 1 Pin 5 Pin 9 Pin 13 Pin 19 Pin 23 Pin 27 Pin 31 RS 422 RX Pin 3 Pin 7 Pin 11 Pin 15 Pin 21 Pin 25 Pin 29 Pin 33 RS 422 RX Pin 4 Pin 8 Pin 12 Pin 16 Pin 22 Pin 26 Pin 30 Pin 34 TABLE B PC PI...

Страница 6: ...ce Note Use each of the six buses carrying data between the data communication ports for one data polling system only If more than one alarm polling system s data routes to a bus the system does not f...

Страница 7: ...ridging between data ports in different modules BRIDGING APPLICATIONS Fig 4 shows a switch setting diagram for bridging applications using half duplex communication Each data port on the data bridge m...

Страница 8: ...8 45 46 A B C D E F REF 7 8 3 2 1 5 VDC RX1 S22 7 TX1 1 2 6 5 Strap 1B 8B REF 11 12 3 2 1 5 VDC RX1 S22 6 TX1 1 2 10 9 Strap 1B 8B REF 3 4 3 2 1 5 VDC RX1 S22 8 TX1 1 2 2 1 Strap 1B 8B DATA DATA DATA...

Страница 9: ...Switch S10 1 On All Switches Off 49 50 47 48 45 46 A B C D E F REF 7 8 3 2 1 5 VDC RX1 S22 7 TX1 1 2 6 5 Strap 1B 8B 3 4 3 2 1 5 VDC RX1 S22 8 TX1 1 2 2 1 Strap 1B 8B RS 232 RS 422 RS 232 RS 422 REF R...

Страница 10: ...TX BA CF CA To External Equipment TTL PORT DATA DATA DATA DATA DATA DATA 5 VDC Buses A F To Other Data Ports Data Port 1 RS232 Strap 1A 8A Data Port 2 RS 232 Strap 1A 8A Unused Two ports are required...

Страница 11: ...onnections If a TTL subassembly bypass card was installed remove the blue hole plug from the front panel subassembly window Install the new subassembly Refer to Fig 6 Ensure the subas sembly connector...

Страница 12: ...s Refer to Fig 7 and Tables C and D for setting straps and switches FIG 7 SWITCH AND STRAP LOCATIONS INSTALLATION CONTINUED 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1...

Страница 13: ...1 3 S4 3 S12 3 S5 3 S13 3 S6 3 S14 3 S7 3 S15 3 S8 3 S16 3 BUS D S1 4 S9 4 S2 4 S10 4 S3 4 S11 4 S4 4 S12 4 S5 4 S13 4 S6 4 S14 4 S7 4 S15 4 S8 4 S16 4 BUS E S1 5 S9 5 S2 5 S10 5 S3 5 S11 5 S4 5 S12 5...

Страница 14: ...20 2 S21 2 BUS C S17 3 S18 3 S19 3 S20 3 S21 3 BUS D S17 4 S18 4 S19 4 S20 4 S21 4 BUS E S17 5 S18 5 S19 5 S20 5 S21 5 BUS F S17 6 S18 6 S19 6 S20 6 S21 6 DUPLEX ON PORTS 1 8 SWITCH S22 8 OFF S22 8 ON...

Страница 15: ...Port 7 RS 422 RX RS 232 RD Port 7 RS 422 TX Port 7 RS 422 TX RS 232 TD Port 6 RS 422 RX Port 6 RS 422 RX RS 232 RD Port 6 RS 422 TX Port 6 RS 422 TX RS 232 TD Port 5 RS 422 RX Port 5 RS 422 RX RS 232...

Страница 16: ...through eight The next eight LEDs labeled TX1 to TX8 respectively indicate transmit TX activity for data ports one through eight The next two LEDs are not labeled and do not function The last two LEDs...

Страница 17: ...oad no subassembly 24 VDC 48 VDC Heat Dissipation full load no subassembly 24 VDC 48 VDC Physical Dimensions Weight Operating Temperature Range Data Inputs and Outputs VALUE 21 to 56 VDC 64 0 mA 80 0...

Страница 18: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...

Отзывы: