background image

P

AGE

 16

44023-1297 <90-00058>

F

IG

. 6 - 44023 PABX/T

RUNK

 I

NTERFACE

 P

IN

 D

ESIGNATIONS

INSTALLATION

56

55

54

53

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

CIRCUIT SIDE
OF PC BOARD

COMPONENT SIDE

OF PC BOARD

C LEAD

DROP XMT, R

A LEAD

DROP XMT, T

2W RING, OUT

2W RING, IN

LINE XMT,R

B LEAD

2W TIP, OUT

2 W TIP, IN

LINE XMT, T

DISTRIBUTION OUT

POWER-UP CLEAR

ON-HOOK TONE INPUT

OFF-HOOK TONE INPUT

- BATTERY

BUSY TONE INPUT

M LEAD, NORMALLY OPEN

ALERT TONE INPUT

ECHO SUPPRESSION

GROUP CALL

STATION CALL

M LEAD

BUSY

CIRCUIT CONTROL OUTPUT

BUSY CONTROL

GROUND

CIRCUIT CONTROL INPUT

DROP RCV, R

MANUAL CLEAR

SUMMING INPUT

SUMMING INPUT

SUMMING INPUT

DROP RCV, T

SUMMING INPUT

M LEAD, NORMALLY CLOSED

LINE RCV, R

E LEAD

LINE RCV, T

Содержание 44023

Страница 1: ...complete information on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1997 by Dantel Inc Dantel is a registered trademark of Dantel Inc IS...

Страница 2: ...The 44023 does not accept subassemblies Strap options lets you Select level range Configure E and M leads Select ground or loop start Select privacy and busy mode Select the conference delay feature...

Страница 3: ...or jacks LINE RCV signals pins 2 and 4 feed through T1 to the pad This pad provides 23 dB of attenuation which prevents overdriving the mute FET You can strap the attenuation out in cases of low line...

Страница 4: ...R24 OUT RCV PAD 23dB IN 8VDC T4 51 53 TEST JACKS DROP MON 8VDC 20 18 POWER SUPPLY REGULATOR 10 8 POWER SUPPLY REGULATOR 18 VDC TP 10 10 VDC 8 VDC TP 9 PINS MON RCV OR XMT TO MODULE CIRCUIT JACK DETAIL...

Страница 5: ...he 44023 processes incoming call signaling in one of two ways with a two wire outside facility or a four wire E and M trunk When an incoming call initiates from a two wire outside facility the ring si...

Страница 6: ...GND START IN OUT 44 48 K1 A B 10VDC 54 50 56 OUT IN LOOP START 200 OC 2 OC 1 52 1 18 14 39 TEST RESET CC1 MANUAL CLR PWR UP CLR E LEAD OUT IN A C B IN OUT ECHO SUPPR CALL GROUP STATION CALL BUSY CONTR...

Страница 7: ...OP RCV respectively The off hook LED also comes on The duration of the alert tone burst proceed to dial signal to the drop is 0 12 seconds This is to ensure that the system is normalized before additi...

Страница 8: ...lephone is lifted off hook This transmits an off hook tone which causes the 44021 Address Decoder to ground pin 22 The CCI pin 18 must also be ground When the 440 system station telephone is taken off...

Страница 9: ...condition Terminate a call before the phone answers by applying a ground to the clear input pin 16 Application of ground returns all functions to normal and outputs a reset pulse at pin 3 The tone dec...

Страница 10: ...stem Functions For an outgoing call the 44023 Seizes the trunk or line when a station or group call input is applied from a decoder Sends an off hook tone to the caller Passes dial tone from the trunk...

Страница 11: ...4 18 19 MANUAL CLEAR PITT 49 55 44020 DTMF DECODER 39 21 56 VDC POWER UP CLEAR 49018 STATION SELECT 12 11 10 9 8 7 6 5 4 3 2 1 BUSY GROUP CALL STATION CALL 39 24 26 22 E CONTROL BATT CCO 1 6 21 33 38...

Страница 12: ...OC2 GND START OC1 LOOP CONT 54 50 52 44 46 48 38 40 36 32 USE ONLY IF NEEDED ALERT TONE BUSY TONE ON HOOK TONE OFF HOOK TONE R 47 45 43 41 B A T R T 2W DROP 6 5 4 3 44099 OR OTHER HOST MODULE 49020 TO...

Страница 13: ...RECEIVE DIST DIST GND GND A11 44023 00 REV__ INC CALL LED OFF HOOK LED XMT LEVEL ADJUST RCV LEVEL ADJUST GND START LP CONT M LEAD BATTERY CONF E CONT IN OUT IN OUT IN OUT OUT IN IN OUT IN OUT BUSY LED...

Страница 14: ...control wink off Other GROUND START PABX using ground start Other CONFERANCE CALLING 10 SEC DELAY When using automatic privacy No delay BUSY CONTROL Common decoder for subscriber module and PABX modul...

Страница 15: ...trol Ground Start Place this strap IN when the outside line uses ground start Even if the loop control strap is OUT this strap must be IN to allow seizing the line in a ground start situation M Lead T...

Страница 16: ...LEAD DROP XMT R A LEAD DROP XMT T 2W RING OUT 2W RING IN LINE XMT R B LEAD 2W TIP OUT 2 W TIP IN LINE XMT T DISTRIBUTION OUT POWER UP CLEAR ON HOOK TONE INPUT OFF HOOK TONE INPUT BATTERY BUSY TONE IN...

Страница 17: ...44023 drop side always in terfaces to the outside world central office or PABX trunk The line side interfaces the 440 CMS or other private network INSTALLATION If you install the 44023 in a 440 CMS M...

Страница 18: ...d other applications Move terminated level meter to the LINE TRANSMIT test points Note Any source device that loads the input will have to be disconnected For multi station packages Move the bridged l...

Страница 19: ...e Dial number for an off net phone Answer off net phone Hang up outside phone Hang up station phone Lift receiver on station phone RESULTS OFF HOOK LED goes off K1 operates seizing the line OFF HOOK L...

Страница 20: ...seconds pass Caller disconnected INC CALL LED goes off After 10 to 80 seconds the call is automa tically terminated OFF HOOK LED comes on Caller hears off hook tone dial tone and ringback tones from...

Страница 21: ...put Power Requirements Idle Full Load Heat Dissipation Idle Full Load Physical Dimensions Weight Operating Temperature Range TABLE HEAD 300 Hz to 3400 Hz 0 5 dB 20 dB 16 dBm to 7 dBm 16 dBm to 7 dBm 1...

Страница 22: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...