background image

41096-0597 <90-00042>

 P

AGE

 5

F

IG

. 1 - 41096 F

UNCTIONAL

 S

CHEMATIC

CIRCUIT DESCRIPTION

UPDATED

RCV T

      8

SPEAKER

  T H R E E   C I R C U I T   O . W .

C O N T R O L   &   S P E A K E R

        M O N I T O R   P A N E L

            * 1 3 - 4 1 0 9 6 - 0 0

ALL
CHANNEL

SELECT
CHANNEL

S4

S5

S6

(P1)

T1

604

604

604

604

604

604

T2

T3

1

2

3

4

5

6

(TB-1)

-BATT

GND

1

3

-21 TO -56VDC

-10 VDC

     SPKR
MON CHAN
   SELECT

- LAMP

+ LAMP

S3

4

1

2

5

6

3

4

1

2

5

4

1

2

5

R
T
T
R

6

3

6

3

- LAMP

- LAMP

+ LAMP

- LAMP

+ LAMP

D I A L

HEADSET

J8

J9

4
1

4
1

A

B

1
2
3

1
2
3

4
5
6

1
2
3
4

HANDSET JACK

RCV
XMT
RCV
XMT

K

L

M

N

XMT R

RCV R

RCV T

XMT T

S/W

R/G

J1

J2

R31
340

XMT T

RCV T

XMT T

RCV T

XMT T

S2

S1

GND

(P4)

(P3)

(P2)

R

R

R

R

R

R

 HOOK
SWITCH

NOTE:  For complete wire instructions, refer

              to installation section of this manual.

FROM
DTSS3A #1

FROM
DTSS3A #2

FROM
DTSS3A #3

GND

FROM

DTSS3A #3

FROM

DTSS3A #2

GND

FROM

DTSS3A #1

GND

Содержание 41096

Страница 1: ...fields For more complete information on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1997 by Dantel Inc Dantel is a registered trademark o...

Страница 2: ...nitor Panel with 3 DTSS3A Terminals 3 digit dialing A13 41096 05 Speaker Monitor Panel with 1 DTSS3A Terminal 6 digit dialing A13 41096 06 Speaker Monitor Panel with 2 DTSS3A Terminals 6 digit dialing...

Страница 3: ...aker with amplifier Two volume controls A fuse A fuse alarm LED The control section includes A push button channel selector DTMF dial Handset Handset cradle Headset jacks Table A shows standard 41096...

Страница 4: ...potentiometer This option allows the selected channel s to be monitored at a louder level The unselected channels are still available for monitoring at a quieter level A fuse and fuse alarm indicator...

Страница 5: ...O 56VDC 10 VDC SPKR MON CHAN SELECT LAMP LAMP S3 4 1 2 5 6 3 4 1 2 5 4 1 2 5 R T T R 6 3 6 3 LAMP LAMP LAMP LAMP LAMP DIAL HEADSET J8 J9 4 1 4 1 A B 1 2 3 1 2 3 4 5 6 1 2 3 4 HANDSET JACK RCV XMT RCV...

Страница 6: ...Order Wire terminals INSTALLING WITH DTSS3A ORDER WIRE TERMINALS When the 41096 Panel is purchased with DTSS3A Order Wire terminals the 41096 Panel comes with the terminals mounted and wired to the pa...

Страница 7: ...ove mounting brackets Remove the mounting brackets from the order wire terminal s and replace them with the mounting brackets supplied with the 41096 panel Install the brackets in the flush mount posi...

Страница 8: ...BRACKET ATTACH ANGLE POSITIONS INSTALLATION SIDE VIEW FRONT TOP VIEW FRONT 19 STANDARD MOUNT SIDE VIEW FRONT 19 FLUSH MOUNT TOP VIEW FRONT 23 STANDARD MOUNT TOP VIEW FRONT SIDE VIEW FRONT 23 FLUSH MOU...

Страница 9: ...Table C Fig 4 and Fig 5 Use wire wrap terminals and leave the modular type telephone jacks available for connecting extensions Dress the wiring across the rear of the 41096 Panel and through the wire...

Страница 10: ...CHANNEL 2 P3 1 P3 2 P3 3 P3 4 P3 5 P3 6 P1 3 P1 4 CHANNEL 3 P4 1 P4 2 P4 3 P4 4 P4 5 P4 6 P1 5 P1 6 TB1 1 TB1 3 TB1 2 TABLE C INTER PANEL WIRING FIG 5 WIRING DIAGRAM DTSS3A 41096 PANEL WIREWRAP TERMI...

Страница 11: ...itor all three order wire channels by turning the ALL CHAN SPEAKER VOLUME CONTROL clockwise until a sufficient level is heard Monitor a single channel by pressing the desired SPEAKER MONITOR CHAN SELE...

Страница 12: ...requency Response Input Impedance VALUE 21 to 56 VDC 75 mA 56 VDC 250 mA 56 VDC 14 3 BTU Hr 56 VDC 47 7 BTU Hr 56 VDC 4 lb 2 oz 8 lb 10 oz 13 lb 2 oz 17 lb 10 oz 17 1 4 W plus mounting hardware x 3 1...

Страница 13: ...41096 0597 90 00042 PAGE 13 NOTES...

Страница 14: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...

Отзывы: