DO Control
If you want to test DO operation manually on the webpage, click the soft buttons of OFF and
ON. Then, you can see that how DO works. These commands also affects the ‘DO status’
because the ‘DO status’ shows the current status of DO.
Friendly Name
You can type any friendly name for DI and DO. This setting helps you to identify which DI or DO
is activated especially when you have multiple product servers on your application program.
DI Trigger Type
You can select the trigger type between normal open (NO) and normal close (NC).
DI Re-arm Period
Use this option to set up detection time interval for event publishers. For example, if you input
‘0,’ it generates events all the time whenever DI is detected. But if you input ’10,’ only 1 event
will be triggered for 10 seconds even if multiple DIs are detected for this 10 seconds.
DO Hold period
The
DO Hold Period
indicates for how long does the DO works. For example, if you input ‘0,’ a
DO device keeps working until a user turns it off manually. If you input ’10,’ a DO device will
work for 10 seconds and finish the operation. However, if you turn a DO device on manually by
using the DO Control button, it will be activated without being affected by the DO hold period
unless you click the OFF button.