background image

4

PUMP AND TUBING

IMPORTANT INFORMATION! 

CHOOSING THE CORRECT PUMP
Your Pressurized Filter System works best within a certain range of flow.  See Table below. Exceeding these 
values will cause leakage or breakage of the filter or its components and void the warranty.  

                                                    MAXIMUM PUMP             

INTAKE PORT               OUTLET PORT 

       

                                OUTPUT  (GAL/HOUR)                

CPF250/PF225 

         

     500

 

 

            

3/4”   

 

 3/4” 

CPF500/PF450 

 

     950   

            

3/4”       

 

 3/4” 

CPF1000/PF900 

 

   1200  

            

3/4”       

 

 3/4” 

CPF2000/PF1900      

   1800  

             

1”  

 

        

    1”   

5

    

  ELECTRICAL 

PRECAUTIONS

Always use a properly grounded outlet. Do not immerse the plug in water. DO NOT REACH INTO THE WATER 
TO REMOVE THE PLUG. TURN OFF CIRCUIT FIRST. A "drip loop" in the cords should be used. A "drip loop" is a 
loop in the cord below the level of the receptacle or plug that prevents water from traveling along the cord. 
The national Electric Code requires that a ground fault interrupter circuit (GFCI) be installed in every branch 
circuit supplying the fountain or pond equipment. Your dealer can supply GFCI units. NEVER REMOVE 
GROUND PIN FROM PLUG.

WARNING: FOR YOUR PROTECTION, ALWAYS UNPLUG THE UNIT FROM ITS POWER SOURCE BEFORE INSTALLING 

OR SERVICING. DO NOT REACH, REMOVE OR DISASSEMBLE BEFORE YOU DISCONNECT POWER.

 Note that the hose fittings of your pressure filter vary depending on your model.  Be sure to check the fitting 
sizes on the pump you choose and pick up the necessary adapters.  
Choose a pump that does not exceed the recommended output for your pressure filter. Danner Manufacturing 
produces a variety of pumps to choose from for your set-up. See our website and/or your dealer for a selection 
of Pondmaster, Hampton Water Gardens and Supreme pumps.

Note that head height, length and diameter of hose and fittings all add to back pressure that can 

overburden your pressure filter or lead to low water flow. To maximize your system do the following:

Avoid using more tubing than is necessary for your filtration set-up.

Use tubing with a diameter that is equal or greater than the intake and output ports of the filter.

Keep tubing as straight as possible to avoid kinks. 

90

o

 elbow connectors add to back pressure and should be kept to a minimum.

Use a bypass valve to bypass the optimal flow of water to the filter, allowing excess flow and pres-

sure to return directly back to the water feature.

PRESSURE FILTER

MODEL

Содержание PONDMASTER HAMPTON CPF250 Series

Страница 1: ...50 05420 84515 05425 84505 CPF1000 PF900 05430 84575 05435 84565 CPF2000 PF1900 05440 84555 05445 84545 PRESSURE FILTER ITEM NO ITEM NO SERIES No UV Clarifier With UV Clarifier Pour afficher les instr...

Страница 2: ...bacteria on the surface of the media that converts dissolved toxic nitrogenous waste to harmless compounds When the bacteria are given the proper environment they grow in a thin biofilm on the surface...

Страница 3: ...AL ACCESSORIES for use with your pressurized filter A B C PRO SKIMMERS B PRO BIOLOGICAL FILTER AND FALLS A PRESSURIZED FILTER CHECK VALVE Provide an enclosure for the water pump and keep debris away f...

Страница 4: ...ump you will need the following items to set up the filter Hoses Maximum11 2 Flexible pressure hose recommended Note that a Valved Bypass must be incorporated into any high volume system with pumps ov...

Страница 5: ...NIT FROM ITS POWER SOURCE BEFORE INSTALLING OR SERVICING DO NOT REACH REMOVE OR DISASSEMBLE BEFOREYOU DISCONNECT POWER Note that the hose fittings of your pressure filter vary depending on your model...

Страница 6: ...Pad fits into the top tray BioMatrix filter ball media is used in the bottom tray or trays depending on your model If your BioMatrix filter ball media is packed in plastic bags empty them evenly into...

Страница 7: ...surfaces of cover and filter case clean of any dirt sand or debris before reassembling BLUE LEVER UP Maximum flow MOVE BLUE LEVER DOWN Reduced flow down to no flow Valve closed BLUE LEVER DOWN PIVOT...

Страница 8: ...e switch by forcing the micro switch Never look directly at UV bulb the UV rays are harmful to eyes and skin TOP CAP ON OFF UV SWITCH UV INDICATOR LIGHT The UV bulb will need replacing We recommend ch...

Страница 9: ...xi mately 1 8 turn until it stops The Quartz Sleeve is now unlocked Quartz Sleeve Removal Bulb Removal 1 Disconnect power remove filter cover and place upside down on a stable surface 3 Invert place B...

Страница 10: ...PF1900 A B C D E F G H I J K L M N O P 15430 15440 15451 15456 15470 15471 Picture Reference Only 15427 15428 15415 15425 15420 15420 Picture Reference Only 15480 15481 Picture Reference Only 15475 No...

Страница 11: ...ler the manufacturer their representatives or any other parties do not constitute warranties and shall not be relied upon by the user and are not part of this contract Neither the seller nor the manuf...

Отзывы: