DIS
User Manual
User Manual CU 6105.docx
56
10.1.2 Command structure (from External Control to CU 6105)
To control the CU an External Control sends commands to CU 6105 included in command lines. Commands lines are
build up in a very simple manner:
Command lines are terminated by Carriage Return <CR> or Line Feed <LF> or both. In order to be able to
communicate with Windows systems, Linux systems or other systems, the CU understands both types of command
line terminations.
Notice also, there is a space between the command and data. If a command does not carry any data, space is possible
but not required.
The CU is not sensitive to upper/lower case.
Example:
mic_on 212<CR>
Turn on microphone a seat 212. Command = 'mic_on', data = '212'. The ‘mic_on’ command carries a seat number as data.
10.1.3 Command structure (from CU 6105 to External Control)
Command lines out of the CU 6105 are just as simple:
Again, to satisfy most systems, the CU terminates command lines by including both <CR> and <LF>.
<command><SP><data><CR>
<command><SP><data><LF>
<SP>
Space - 0x20 = 32
<CR>
Carriage return - 0x0D = 13
<LF>
Line Feed - 0x0A = 10
<command><SP><data><CR><LF>
<SP>
Space - 0x20 = 32
<CR>
Carriage return - 0x0D = 13
<LF>
Line Feed - 0x0A = 10