![Danfoss VLT Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/danfoss/vlt/vlt_training-manual_3508323031.webp)
VLT Installation
Rev.02
29
North America
Motion Controls
Confidential / Property of Danfoss Drives A/S
Mechanical Installation (Mounting)
• Check wall strength and hardware to support the weight
• See Instruction Manual index, “Mechanical Installation” for
more details.
• Most VLT are mounted vertically- exception de-central.
• Cold Plate are mounted in any position but must be flush.
4) Installation Checks
d. Mounting
4) Installation Checks
d. Mounting
In order to provide proper cooling, most drives are mounted vertically, unless
otherwise stated in the VLT Instruction Manual. In is important to check the wall
strength and mounting hardware to insure it can handle the weight of the drive.
Mechanical dimensions of the VLT and of the mounting holes are provided in the
Instruction Manual.
Some drives have Cold Plate technology, such as the 2800, which can be mounted in
any position, vertical, horizontal, etc, but it must be mounted flush to a surface that
can absorb heat.
If heat-sink fins are present on the back of the drive, it must be mounted to a back
plate which causes a chimney effect and proper cooling. Drives that include a
bypass or other option enclosure are generally factory-mounted to a back plate.