![Danfoss VLT Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/danfoss/vlt/vlt_training-manual_3508323012.webp)
VLT Installation
Rev.02
10
North America
Motion Controls
Confidential / Property of Danfoss Drives A/S
Compare VLT number with what was ordered.
Look for the RED label, typically on the Top or Left Side
Catalog Order Number System
Example:
- XXXX–P-T5-B20–ST-R0–DL-F00-A00-C0
Series: VLT, FC, FCM, FCD
Model Number ---------------------|
Application --------------------------------|
P – Process; F - Flux; A - AQUA; G – Graham; H - HVAC
AC Line Voltage -----------------------------|
T2: 3 phase 200 – 240 Vac
T4: 3 phase 380 – 480 Vac
T5: 3 phase 380 – 500 Vac
T6: 3 phase 550 – 600 Vac
Enclosure (index mechanical dimensions)--|
B20: Bookstyle Chassis (IP20)
C00: Compact Chassis (IP 00)
C20: Compact Protected Chassis (IP 20)
CN1: Compact NEMA 1 (IP 20)
C54: Compact NEMA 12 (IP 54)
3) Pre-Installation Checks
d. Compare drive
Hardware – ST
DE
= Fuse/Disc, 24V, Loadshare, DBrake;
DX
= Fuse/Disc, 24V, Loadshare;
EB
= 24V, Loadshare, DBrake;
EX
= 24V, Loadshare;
PB
= Fuse/Disc, 24V, DBrake;
PD
= Fuse/Disc, 24V;
PF
= 24V, Fuse;
PS
= 24V;
SL
= 24V, Loadshare;
ST
= No
options;
SB
= DBrake
RFI Filter – R0
R0
means no extra filter
R1
adds 1A filter
R3
adds both 1A and 1B filter
Display – DL
DL
means with LCP display
D0
is without the LCP
Fieldbus Option – F00
F00
= none;
F10
= Profibus DP/FMS;
F20
= ;
F30
= DeviceNet;
F40
= LonWorks FTP;
F41
= LonWorks 78 kbps;
F42
= LonWorks 1.25mbps
Application Option – A00
A00
= none;
A10
= Programmable Sync/Pos Card;
A11
= Synchronizing card;
A12
= Positioning Card;
A30
= 1 Relay Card;
A31
= 4 Relay Card;
A32
= Cascade Controller Card
Conformal Coating – C0
C0
means no coating
C1
has coating
Содержание VLT
Страница 1: ...05 0 0 530 4 7 5 OTUBMMBUJPO 5SBJOJOH VJEF...