9 Specifications
9.1 Nameplate
The nameplate on the VLT® OneGearDrive® is corrosion-proof. It is made of a special plastic, approved for hazardous areas by the
Physikalisch-Technische-Bundesanstalt (PTB).
e30bb851.16
OneGearDrive
123X5678000101Q140
Made in Italy VAI
Danfoss A/S
6430 Nordborg, Denmark
Type OGDSK231K131401L06RXTB1P3S9010H1B2201XXX
P/N: 123X5678
U= 3x380..480VAC
24kg
max= 2.3kW
n
max
= 96rpm
f
max
= 250Hz
t
amb
= 40˚C
IP67
i= 31.13
KTY 84-130
S/N: 000101Q140
BRK 220VDC
I
nom
= 5.5A
105˚C (A)
V210
M
max
= 380Nm
1
2
3
4
5
6
7
8
9
P3=3.1 L Optileb
Inverter Duty Motor
VLT
Illustration 14: Example Nameplate
1
Supply voltage
2
Power
3
Nominal motor current
4
Motor frequency
5
Gear ratio
6
Brake data
7
Output torque
8
Output speed
9
Mounting position and oil data
9.2 Storage
If the VLT® OneGearDrive® is to be stored, ensure a dry, dust free, and well-ventilated environment. If the temperature in the storage
space exceeds the normal range of –20 °C (–4 °F) to 40 °C (+104 °F) for an extended period or varies frequently, employ the meas-
ures before start-up specified in
6.1 Measures before Commissioning
, even after short storage times.
Damage sustained during storage:
The life of the oils and seals is reduced with longer storage times.
There is a risk of fracture at low temperatures (under approximately –20 °C (–4 °F).
If the VLT® OneGearDrive® is being stored for an extended time before start-up, increased protection against damage by corrosion
or humidity can be achieved by observing the information in
and
serve the instructions in this Operating Guide.
The actual load depends strongly on local conditions, therefore the time period stated is only a guiding value. This period does not
include any extension of the warranty.
If disassembly is necessary before start-up, contact Danfoss Service.
9.2.1 Measures during Storage
Turn the VLT® OneGearDrive® 180° every 12 months so that the oil in the gear unit covers the bearings and gear wheels that were
previously positioned on top. Also, turn the output shaft manually to churn the rolling-contact bearing grease and distribute it
evenly.
9.2.2 Measures after Storage
Repair any damage to the exterior paint layer or to the rust protection of the bright hollow shafts.
Check that the VLT® OneGearDrive® contains the correct amount of oil and confirm the correct mounting position (see
AQ347551551757en-000101 / 130R0239 | 29
Danfoss A/S © 2020.12
Specifications
VLT® OneGearDrive®
Operating Guide
Содержание VLT OneGearDrive
Страница 1: ...Operating Guide VLT OneGearDrive drives danfoss com...
Страница 2: ......