4.7.3 Dimensions of Assembly Kit for Imperial Shafts
Table 5: Dimensions of Assembly Kit Items for Imperial Shafts [inch]
Type
Stainless steel retaining ring
Lock washer
(1)
Fixing screw
(1)
Key
(1)
OGD-I1
1.250 x 0.050
0.375
0.500–13 x 1.1875 [M12 x 30]
0.2500 x 0.2500 x 3.937
(2)
OGD-I2
1.4375 x 0.050
0.500
0.500–13 x 1.3750 [M12 x 35]
0.3750 x 0.3750 x 3.937
(2)
OGD-I3
1.500 x 0.050
0.625
0.625–11 x 1.6250 [M16 x 35]
0.3750 x 0.3750 x 3.937
(2)
1
Not included
2
Key length required for b
min
4.10 Dimensions of the Imperial Shaft and Disk
. Adapt the key length according to the shaft length used.
The dimensions shown could differ from the customer conditions and must potentially be changed by the customer.
4.8 Mounting Instructions
Procedure
Rotate the disk and fit it against the retaining ring. Both items are included in every delivery.
Attach the fixing screw and lock washer (not included).
N O T I C E
The fixing screw and washer required depend on the length and size of the shaft. For further information, refer
to the mounting arrangement (see
e30bd420.12
b
k
30
o
l
Øm
e
Øa
h6
e
f
C
P9
d+0.2
x
edges cut
i
h
g
60
o
Chamfer sized to outer
diameter of thread
bmax
bmin
Øo-0.2
Disc
Shaft
n
Øp
[d+0.0078]
[Øo-
0.0078]
Illustration 2: Axial Fastening
max 0.2 mm
e30bd764.11
[0.0078]
Illustration 3: Maximum Eccentricity of the Conveyor Shaft
AQ347551551757en-000101 / 130R0239 | 13