background image

1 Safety Warnings

1.1  Purpose of this Installation Guide

The purpose of this installation guide is to describe the
installation of the VLT

®

 OneGearDrive ExtensionBox.

NOTICE

The information is limited to that required for qualified
personnel in normal working situations. Contact Danfoss
for further assistance.

The full operating instructions with more detailed
information are available on the Danfoss website:

vlt-drives.danfoss.com/Support/Technical-Documentation/

Compliance with the information in this installation guide
is a prerequisite for:

Trouble-free operation.

Recognition of product liability claims.

Therefore, read this manual before working on or with the
OneGearDrive.

VLT

®

 is a registered trademark.

1.2  Safety Symbols

The following symbols are used in this manual:

WARNING

Indicates a potentially hazardous situation that could
result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation that could
result in minor or moderate injury. It can also be used to
alert against unsafe practices.

NOTICE

Indicates important information, including situations that
can result in damage to equipment or property.

1.3  Intended Use

The OneGearDrive is intended for commercial installations
unless otherwise expressly agreed. It complies with the
standards of the series EN 60034/DIN VDE 0530. Use in a
potentially explosive atmosphere is forbidden if not
expressly intended for this purpose. The OneGearDrive is

designed for ambient temperatures from –20 

˚

C to 40 

˚

C

and for installation heights up to 1000 m above sea level.

Danfoss assumes no responsibility of any sort for damage
attributable to improper use.

CAUTION

Low voltage machines are components for installation in
machines in the sense of the machinery directive
2006/95/EC.

Do not use the machine until conformity of the
final product with this directive is established
(refer to EN 60204-01).

1.4  Qualified Personnel

All necessary work on electric drive units must only be
performed by adequately qualified personnel (for example,
electrical engineers as specified in draft EN 50 110-1/DIN
VDE 0105), who have the operating instructions provided
and other product documentation available during any
corresponding work, and who are obliged to abide by the
instructions contained therein. Qualified personnel are
persons who are authorised due to training, experience,
and instruction, as well as their knowledge of relevant
standards, rules, accident-prevention regulations, and
operating conditions.

1.5  Safety Precautions

WARNING

HIGH VOLTAGE

High voltage, which can lead to death or serious injury,
is present on the connectors.

Before working on the power connectors
(disconnecting or connecting the cable to the
OneGearDrive), disconnect the supply to the
frequency converter and wait for the discharge
time to elapse (see the frequency converter
operating instructions).

Installation, start-up, maintenance, and
decommissioning must only be performed by
qualified personnel.

1.6  Service and Support

Contact the local service representative for service and
support:

vlt-drives.danfoss.com/Support/Service/

Safety Warnings

VLT

®

 OneGearDrive ExtensionBox

2

Danfoss A/S © 02/2015 All rights reserved.

MI75A102

1

1

Содержание VLT OneGearDrive ExtensionBox

Страница 1: ...MAKING MODERN LIVING POSSIBLE Installation Guide VLT OneGearDrive ExtensionBox vlt drives danfoss com ...

Страница 2: ......

Страница 3: ...upport 2 2 Installation 3 2 1 Items Supplied 3 2 2 Mounting 3 2 2 1 Torque Arm 3 2 2 2 ExtensionBox 4 2 2 3 VLT OneGearDrive 5 3 Specifications 8 3 1 General Specifications and Environmental Conditions 8 3 2 Dimensions 8 3 2 1 ExtensionBox 8 3 2 2 Adapter Flange 9 3 2 3 Torque Arm for ExtensionBox 9 Contents Installation Guide MI75A102 Danfoss A S 02 2015 All rights reserved 1 ...

Страница 4: ... C and for installation heights up to 1000 m above sea level Danfoss assumes no responsibility of any sort for damage attributable to improper use CAUTION Low voltage machines are components for installation in machines in the sense of the machinery directive 2006 95 EC Do not use the machine until conformity of the final product with this directive is established refer to EN 60204 01 1 4 Qualifie...

Страница 5: ...ves with a 40 mm hollow shaft The minimum shaft length is 130 mm and the maximum shaft length is 150 mm All other specifications can be found in chapter Assembly Kit in the VLT OneGearDrive Operating Instructions 2 2 1 Torque Arm 54 2 13 1 2 130BE120 10 1 Torque arm fastening set 2 Customer support frame Illustration 2 1 ExtensionBox with Torque Arm and OneGearDrive Take the dimensions from chapte...

Страница 6: ...he ExtensionBox with Torque Arm 2 2 2 ExtensionBox 1 Grease the conveyor shaft 2 Mount the ExtensionBox to the conveyor shaft and fix it with the delivered retaining ring and disc NOTICE The screw 3 is not supplied and depends on the conveyor shaft length Refer to the chapter Assembly Kit in the VLT OneGearDrive Operating Instructions for further information 3 Assemble the ExtensionBox in 30 steps...

Страница 7: ...pter flange screw positions 3 0 30 130BE122 10 130BE124 10 P3 115 4 53 200 7 87 6x60 130BE126 10 130BE123 10 6 0 6 0 130BE125 10 P1 P2 3 0 30 130BE122 10 130BE125 10 P1 P2 130BE127 10 115 4 53 200 7 87 12x30 130BE123 10 6 0 6 0 130BE124 10 P3 Table 2 1 Possible Adapter Flange Positions 2 Tighten all 6 screws as shown in Illustration 2 3 3 Grease the ExtensionBox shaft 4 Mount the OneGearDrive to t...

Страница 8: ...dapter 2 6 Washer DIN 125 A10 5 3 6 Adapter screw DIN 912 M10 x 30 tightening torque 20 Nm Illustration 2 3 Assembly of the Adapter Flange to the OneGearDrive Installation VLT OneGearDrive ExtensionBox 6 Danfoss A S 02 2015 All rights reserved MI75A102 2 2 ...

Страница 9: ... of the Adapter Flange to the ExtensionBox 5 Fasten the adapter flange 5 with the adapter screws supplied 6 Remove the eye bolt 1 from the ExtensionBox and the OneGearDrive 7 Fit the plastic cap 2 supplied to close the hole on the ExtensionBox 8 Fit the hollow shaft cover 3 to the ExtensionBox Refer to the VLT OneGearDrive Operating Instructions for further information Installation Installation Gu...

Страница 10: ... 3 1 General Specifications and Environmental Conditions 3 2 Dimensions 3 2 1 ExtensionBox All dimensions are in mm inch 380 350 182 364 562 182 543 4 224 4 21 39 8 83 7 17 7 17 13 78 14 33 22 13 14 96 130BE130 10 Illustration 3 1 ExtensionBox Dimensions Specifications VLT OneGearDrive ExtensionBox 8 Danfoss A S 02 2015 All rights reserved MI75A102 3 3 ...

Страница 11: ...ange Dimensions 3 2 3 Torque Arm for ExtensionBox All dimensions are in mm inch 380 14 96 350 13 78 86 5 3 41 60 2 36 33 5 1 32 8 0 31 13 5 0 53 1 3 5 8 5 3 5 164 6 46 R 4 0 1 5 7 1 9 2 7 5 6 31 5 1 24 0 5 0 2 0 0 0 7 8 9x30 30 0 0197 130BE132 10 Illustration 3 3 Torque Arm Dimensions Specifications Installation Guide MI75A102 Danfoss A S 02 2015 All rights reserved 9 3 3 ...

Страница 12: ...ducts already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respective companies Danfoss and the Danfoss logotype are trademarks of Danfoss A S All rights reserved Danfoss A S Ulsnaes 1 DK 6300 Graasten vlt drives danfoss com MI75A102 130R0615 MI75A102 02 2015 ...