Illustration 7: Example of Combined Topologies

AN427641276310en-000101 / 175R1187 | 33

Danfoss A/S © 2022.10

Network Design

EtherNet/IP Module

Installation Guide

Содержание VLT MCD 201

Страница 1: ...Installation Guide EtherNet IP Module VLT Compact Starter MCD201 MCD 202 and VLT Soft Starter MCD 500...

Страница 2: ......

Страница 3: ...ts 11 Cables 11 EMC Precautions 12 Network Establishment 12 Addressing 12 Device Configuration 13 Before Configuring the Device 13 Configuration Methods 13 On board Web Server 13 Connect to the Device...

Страница 4: ...mand 23 Bytes 2 3 Reserved 23 Command Examples 24 Status Information Assembly Instance 154d 24 Bytes 0 1 Starter State 24 Bytes 2 3 Reserved 25 Bytes 4 7 Motor Current 25 Bytes 8 9 Trip Code 25 Bytes...

Страница 5: ...3 10 4 10 5 10 6 Specifications 34 Enclosure 34 Mounting 34 Connections 34 Network 34 Power 34 Certification 34 AN427641276310en 000101 175R1187 5 Danfoss A S 2022 10 Contents EtherNet IP Module Inst...

Страница 6: ...while the soft starter is connected to mains voltage may cause personal injury Before attaching or removing accessories isolate the soft starter from mains voltage W A R N I N G RISK OF PERSONAL INJU...

Страница 7: ...el on the side of the module 175G9906 MCD EtherNet IP module Monitor and control the soft starter over an EtherNet IP connection 175G9907 MCD EtherNet IP module Monitor and control the soft starter ov...

Страница 8: ...ft starter 2 Network switch 3 IoT connection MQTT OPC UA 4 Industrial Ethernet connection to programmable logic controller 5 TCP connection to VLT Motion Control Tool MCT 10 Refer to the VLT Motion Co...

Страница 9: ...t may damage the equipment Remove mains and control voltage from the soft starter before installing or removing options accessories Procedure Remove control power and mains supply from the soft starte...

Страница 10: ...retaining clips to secure the module to the soft starter e77ha835 10 Connect Ethernet Port 1 or Port 2 on the EtherNet IP module to the network Apply control power to the soft starter AN427641276310en...

Страница 11: ...RJ45 Ethernet ports 25 17 18 2 3 1 e77ha621 10 Illustration 3 Connecting MCD 500 1 Soft starter remote mode 17 18 Stop input 25 18 Reset input 2 EtherNet IP module 3 RJ45 Ethernet ports 4 2 Network C...

Страница 12: ...must establish communications directly with each device before the device can participate in the network 4 4 Addressing Each device in a network is addressed using a MAC address and an IP address The...

Страница 13: ...HCP The web server can configure the IP address and messaging settings for MQTT or OPC UA operation If it is not possible to connect to the web server use the Ethernet Device Configuration software to...

Страница 14: ...Net IP module supports multiple users and levels of privilege Users can view the home screen and IP settings Supervisors can view the home screen and IP settings and they can change configuration sett...

Страница 15: ...te an account Set privileges user supervisor administrator as appropriate Click Save changes 5 3 2 2 Deleting a User Procedure Connect to the web server and click Administration Select the required en...

Страница 16: ...addressing tick the DHCP checkbox Click Submit to send the new settings to the device 5 3 4 Configure IoT Settings The EtherNet IP module supports soft starter status monitoring via IoT The device can...

Страница 17: ...enable MQTT client operation The MQTT client is enabled by default Click Connection and configure the settings as required Click Connections Actions to select which information the device should publi...

Страница 18: ...ere is no connection to the web server and the soft starter cannot be accessed physically use the Ethernet Device Configuration Tool to scan the network and identify the device Changes made via the Et...

Страница 19: ...he Ethernet Device Configuration Tool Click Search Devices e77ha641 10 The software searches for connected devices Use the IP address to connect to the device via the web server AN427641276310en 00010...

Страница 20: ...eds Once the EDS file has been loaded the individual EtherNet IP module must be defined 6 2 Assembly Objects Table 2 Supported Assembly Objects Description Class Instance Type Maximum size Output Ori...

Страница 21: ...the data is overwritten or the device is reinitialized The EtherNet IP module will not transfer successive duplicate commands to the soft starter If the soft starter is started via fieldbus communicat...

Страница 22: ...scription Link x Off No network connection On Connected to a network TX RX x Flashing Transmitting or receiving data AN427641276310en 000101 175R1187 22 Danfoss A S 2022 10 Operation EtherNet IP Modul...

Страница 23: ...Description Class Instance Type Maximum size Output Originator Target 04d 0x04 104d 0x68 Integer 2 4 bytes Input Target Originator 04d 0x04 154d 0x9A Integer 6 12 bytes 8 2 2 Control Commands Assembl...

Страница 24: ...e 154d To retrieve status data from the soft starter use assembly class 04d 0x04 assembly instance 154d 0x9A attribute 03d 0x03 8 2 3 1 Bytes 0 1 Starter State Bits Function Details 0 Ready 0 Not read...

Страница 25: ...tion Details 0 15 Trip code See the chapter Trip Codes 8 2 3 5 Bytes 10 11 Reserved Bits Function Details 0 15 Reserved 8 3 Explicit Messaging Acyclic Operation This section provides information on ob...

Страница 26: ...ctory parameters parameter group 20 may cause unpredictable behavior in the soft starter Con sult a local supplier before adjusting the Factory parameters 8 3 2 2 Class 103 Objects Read Only Class 103...

Страница 27: ...ower scale 0 Multiply power by 10 to get W 1 Multiply power by 100 to get W 2 Power kW 3 Multiply power by 10 to get kW 103 121 100 Power factor 103 122 100 Reserved 103 123 100 Phase 1 current 103 12...

Страница 28: ...software version Remote LCP if installed 104 106 100 Major software version Expansion card if installed 104 107 100 Minor software version Expansion card if installed 104 108 100 Model rating 104 109...

Страница 29: ...out of range of the mapped register 15d 0x0E Attribute not settable This code only applies to the service Set Attribute Single It is returned if the mapped register is read only 20d 0x14 Attribute not...

Страница 30: ...er communication 114 Network communication 115 L1 T1 shorted 116 L2 T2 shorted 117 L3 T3 shorted 118 Motor 2 overload 119 Time overcurrent bypass overload 121 Battery clock 122 Thermistor circuit AN42...

Страница 31: ...to another device until all devices are connected e77ha629 10 Illustration 5 Example of Line Topology N O T I C E The device has an integrated switch to allow data to pass through in line topology Th...

Страница 32: ...etwork switch The 2nd Ethernet port of the module connects to another device which in turn connects to another device until all devices are connected The final device connects back to the switch The d...

Страница 33: ...e77ha631 10 Illustration 7 Example of Combined Topologies AN427641276310en 000101 175R1187 33 Danfoss A S 2022 10 Network Design EtherNet IP Module Installation Guide...

Страница 34: ...ontacts Gold flash Network RJ45 10 4 Network Link speed 10 Mbps 100 Mbps auto detect Full duplex Auto crossover 10 5 Power Consumption steady state maximum 35 mA 24 V DC Reverse polarity protected Gal...

Страница 35: ...AN427641276310en 000101 175R1187 35 Danfoss A S 2022 10 Specifications EtherNet IP Module Installation Guide...

Страница 36: ...rinted material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes...

Отзывы: