4 Mechanical Installation
4.1 Transport and Delivery
4.1.1 Items Supplied
The items supplied for the ISD 510 servo system are:
•
ISD 510 servo drives
•
Servo Access Box (SAB) including connectors
•
This manual
•
Feed-in (hybrid) cable
•
Loop (hybrid) cable
•
Blind caps for connectors M8, M12, and M23
The packaging unit depends on the number of servo
drives delivered. Save the packaging for use in the event of
product return.
4.1.2 Transport
•
Always use means of transport and lifting gear
with sufficient load capacity to transport the
servo drives and the SAB.
•
Avoid vibration during transport.
•
Avoid heavy impacts and blows.
4.1.3 Inspection on Receipt
1.
After receiving the delivery, immediately check
whether the items supplied match the shipping
documents. Danfoss does not honor claims for
faults registered later.
2.
Register a complaint immediately:
•
With the carrier if there is visible
transport damage.
•
With the responsible Danfoss represen-
tative if there are visible defects or the
delivery is incomplete.
4.2 Safety Measures during Installation
Always observe the safety instructions in
during installation.
Pay particular attention to ensuring that the following
points are always observed:
•
Installation may only be performed by qualified
personnel - see
chapter 2.5 Qualified Personnel
•
Installation must be performed with due care and
attention.
•
All safety regulations and protective measures
must be complied with, and the environmental
conditions must be observed.
•
The manual is read and understood.
4.3 Installation Environment
The installation must provide the following environmental
conditions to allow the ISD 510 servo system to be
operated safely and efficiently.
Servo Drive
•
The allowable operating ambient temperature
range and vibration levels must not be exceeded
(see
chapter 11.1.5 General Specifications and
for further information).
•
The allowable relative humidity range is 3–93%,
non-condensing.
•
Unrestricted ventilation must be available.
•
The mounting structure must be suitable for the
application, adequately rigid, and so on.
SAB
•
The allowable operating ambient temperature
range and vibration levels must not be exceeded
(see
chapter 11.2.4 General Specifications and
for further information).
•
The allowable relative humidity range is 5–93%,
non-condensing.
•
Minimum 100 mm space is required above and
below the SAB (see
chapter 4.5.1 Installation and
for further information).
Contact Danfoss if it is not possible to comply with these
environmental conditions.
Mechanical Installation
Operating Instructions
MG75K102
Danfoss A/S © 12/2015 All rights reserved.