Pa
r.
No.
#
Para
mete
r descripti
on
De
fault va
lue
4-
se
t-
up
FC
3
02
onl
y
Cha
nge
durin
g
ope
rati
on
Conve
r-
sio
n index
Type
15
-0* Ope
rat
in
g D
ata
15-
00
Op
erat
ing
H
ours
0 h
All
set
-ups
FALSE
74
Ui
nt32
15-
01
Runn
in
g Hours
0 h
All
set
-ups
FALSE
74
Ui
nt32
15-
02
kWh Co
un
te
r
0 kWh
All
se
t-
ups
FALSE
75
Ui
nt32
15-
03
Pow
er-
ups
0 N/
A
All
set
-ups
FALSE
0
Ui
nt32
15-
04
O
ver Te
mp
s
0
N/
A
All
se
t-
ups
FALSE
0
U
in
t16
15-
05
Ove
r Vo
lts
0 N/
A
All
set
-ups
FALSE
0
Ui
nt16
15-
06
R
es
et kWh Co
un
te
r
[0] Do
no
t rese
t
All set
-ups
TRUE
-
Uint8
15-
07
Rese
t R
unning Ho
urs Co
unte
r
[0]
Do
no
t re
set
All
set
-ups
TRUE
-
Ui
nt8
15
-1* Dat
a Log
S
ett
in
gs
15-
10
Logg
ing S
ourc
e
0
2 set-
up
s
TRUE
-
Ui
nt16
15
-1
1
Logg
ing I
nte
rval
Ex
pressi
on
Limit
2
se
t-u
ps
TRUE
-3
Ti
m
D
15-
12
Trigg
er E
vent
[0
] FALSE
1 set-
up
TRUE
-
Ui
nt8
15-
13
Lo
gg
in
g
Mo
de
[0
] L
og
al
ways
2 set-
up
s
TR
U
E
-
U
int8
15-
14
Sa
mp
le
s Be
fo
re
Trig
ge
r
50 N/A
2 set-
up
s
TRUE
0
Ui
nt8
15
-2* Hist
ori
c Log
15-
20
Hi
stori
c Log
: Event
0 N/
A
All
set
-ups
FALSE
0
Ui
nt8
15-
21
Hi
stori
c Lo
g:
Value
0
N/
A
All
se
t-
ups
FALSE
0
U
in
t32
15-
22
Hi
stori
c Log
:
Ti
me
0 ms
All
set
-ups
FALSE
-3
Ui
nt32
15
-3* Fau
lt
Log
15-
30
Fa
ul
t Lo
g: E
rror
Co
de
0 N/
A
All
set
-ups
FALSE
0
Ui
nt8
15-31
Fault Lo
g: Value
0 N/A
All
set
-ups
FALSE
0
Int
16
15-
32
Fault Log
:
Ti
me
0 s
All
set
-ups
FALSE
0
Ui
nt32
15
-4* Dr
iv
e I
d
en
ti
fi
cat
ion
15-
40
FC Ty
pe
0 N/
A
All
set
-ups
FALSE
0
Vi
sS
tr
[6
]
15-
41
Po
we
r Se
ctio
n
0
N/
A
All
se
t-
ups
FALSE
0
Vi
sS
tr[20
]
15-
42
Vol
ta
ge
0 N/
A
All
set
-ups
FALSE
0
VisS
tr
[2
0]
15-
43
So
ft
w
are
Ve
rsio
n
0 N/
A
All
se
t-
ups
FALSE
0
VisStr[5]
15-
44
Ord
ere
d Typec
ode St
ring
0 N/
A
All
set
-ups
FALSE
0
VisS
tr
[4
0]
15-
45
Ac
tu
al Typ
eco
de
String
0 N/
A
All
se
t-
ups
FALSE
0
Vi
sS
tr[40
]
15-
46
Adj Freq Dr
Orderi
ng
No
.
0 N/
A
All
set
-ups
FALSE
0
Vi
sS
tr
[8
]
15-47
Power C
ard Orderi
ng
No.
0
N/
A
All
set
-ups
FALSE
0
VisStr[8]
15-
48
LCP ID
N
um
.
0 N/
A
All
set
-ups
FALSE
0
VisS
tr
[2
0]
15-
49
SW I
D
Contro
l Card
0
N/
A
All
se
t-
ups
FALSE
0
Vi
sS
tr[20
]
15-
50
SW ID
Po
we
r Card
0 N/
A
All
set
-ups
FALSE
0
VisS
tr
[2
0]
15-
51
Ad
j Freq
Dr
Se
rial No.
0 N/
A
All
se
t-
ups
FALSE
0
Vi
sS
tr[10
]
15-
53
Power C
ard Se
ria
l Number
0 N/
A
All
set
-ups
FALSE
0
VisS
tr
[1
9]
4.3.14.
15-** Drive Information
VLT
®
Automation Drive FC 300
Instruction Manual High Power
4. How to Program
MG.33.U1.22 - VLT
®
is a registered Danfoss trademark.
101
4