parameter 8-50 Coasting Select
to
parameter 8-56 Preset
Reference Select
.
The effect of control mode after the function of
parameter 8-50 Coasting Select
,
, and
parameter 8-52 DC Brake Select
are shown in
, and
If
[0] Digital input
is selected, terminals control the coast
and DC brake functions.
Terminal
Bit 02/03/04
Function
0
0
Coast/DC brake/Q-Stop
0
1
Coast/DC brake/Q-Stop
1
0
No Coast/DC brake/Q-Stop
1
1
No Coast/DC brake/Q-Stop
Table 8.3 Parameter 8-50/51/52 Setting:
[0] Digital Input
If
[1] Bus
is selected, commands are activated only when
given via the control word.
Terminal
Bit 02/03/04
Function
0
0
Coast/DC brake/Q-Stop
0
1
No Coast/DC brake/Q-Stop
1
0
Coast/DC brake/Q-Stop
1
1
No Coast/DC brake/Q-Stop
Table 8.4 Parameter 8-50/51/52 Setting: [1] Bus
If
[2] Logic AND
is selected, activate both signals to perform
the function.
Terminal
Bit 02/03/04
Function
0
0
Coast/DC brake/Q-Stop
0
1
No Coast/DC brake/Q-Stop
1
0
No Coast/DC brake/Q-Stop
1
1
No Coast/DC brake/Q-Stop
Table 8.5 Parameter 8-50/51/52 Setting: [2] Logic AND
If
[3] Logic OR
is selected, activation of 1 signal activates
the function.
Terminal
Bit 02/03/04
Function
0
0
Coast/DC brake/Q-Stop
0
1
Coast/DC brake/Q-Stop
1
0
Coast/DC brake/Q-Stop
1
1
No Coast/DC brake/Q-Stop
Table 8.6 Parameter 8-50/51/52 Setting: [3] Logic OR
NOTICE
Coasting, Quick Stop, and DC brake functions are active
for logic 0’.
The effect of control mode after the function of
parameter 8-53 Start Select
and
are shown in
,
,
, and
If
[0] Digital Input
is selected, terminals control the start
and reversing functions.
Terminal
Bit 06/15
Function
0
0
Stop/Counter-clockwise
0
1
Stop/Counter-clockwise
1
0
Start/Clockwise
1
1
Start/Clockwise
Table 8.7 Parameter 8-53/54 Setting: [0] Digital input
If
[1] Bus
is selected, commands are activated only when
given via the control word.
Terminal
Bit 02/03/04
Function
0
0
Stop/Counter-clockwise
0
1
Start/Clockwise
1
0
Stop/Counter-clockwise
1
1
Start/Clockwise
Table 8.8 Parameter 8-53/54 Setting: [1] Bus
If
[2] Logic AND
is selected, activate both signals to perform
the function.
Terminal
Bit 02/03/04
Function
0
0
Stop/Counter-clockwise
0
1
Stop/Counter-clockwise
1
0
Stop/Counter-clockwise
1
1
Start/Clockwise
Table 8.9 Parameter 8-53/54 Setting: [2] Logic AND
If
[3] Logic OR
is selected, activation of 1 signal activates
the function.
Terminal
Bit 02/03/04
Function
0
0
Stop/Counter-clockwise
0
1
Start/Clockwise
1
0
Start/Clockwise
1
1
Start/Clockwise
Table 8.10 Parameter 8-53/54 Setting: [3] Logic OR
The effect of control mode after the function of
parameter 8-55 Set-up Select
and
parameter 8-56 Preset
Reference Select
are shown in
,
, and
:
If
[0] Digital input
is selected, the terminals control the set-
up and preset reference functions.
Troubleshooting
VLT
®
DeviceNet MCA 104
42
Danfoss A/S © 12/2015 All rights reserved.
MG92F102