![Danfoss VLT CDS 803 Скачать руководство пользователя страница 71](http://html.mh-extra.com/html/danfoss/vlt-cds-803/vlt-cds-803_design-manual_508011071.webp)
8 General Specifications
8.1 Mains Supply Specifications
8.1.1 Mains Supply 3x200–240 V AC
Frequency converter
4 TR/VZH028
5 TR/VZH035
6.5 TR/VZH044
Typical shaft output [kW]
6.0
7.5
10
IP20 enclosure protection rating
H4
H4
H5
Maximum cable size in terminals (mains, compressor) [mm
2
/AWG]
16/6
16/6
16/6
Output current
Continuous
(3x200–240 V) [A]
20.7
25.9
33.7
Intermittent
(3x200–240 V) [A]
–
–
37.1
Maximum input current
Continuous
3x200–240 V) [A]
23.0
28.3
37.0
Intermittent
(3x200–240 V) [A]
–
–
41.5
Maximum mains fuses, see
Estimated power loss [W], Best case/typical
1)
182/
204
229/
268
369/
386
Weight enclosure protection P20 [kg/(lb)]
7.9 (17.4)
7.9 (17.4)
9.5 (21)
Efficiency [%], best case/
typical
1)
97.3/
97.0
98.5/
97.1
97.2/
97.1
Table 8.1 3x200–240 V AC
1) At rated load conditions.
General Specifications
Design Guide
MG18N202
Danfoss A/S © 12/2015 All rights reserved.
69
8
8