Par.
No. #
Parameter description
Default value
2-set-up
Change
during
operation
Conver-
sion index
Type
4-4* Adj. Warnings 2
4-40
Warning Freq. Low
30 Hz
All set-ups
TRUE
-1
uint16
4-41
Warning Freq. High
200 Hz
All set-ups
TRUE
-1
uint16
4-5* Adj. Warnings
4-50
Warning Current Low
0 A
All set-ups
TRUE
-2
Uint32
4-51
Warning Current High
ExpressionLimit
All set-ups
TRUE
-2
Uint32
4-54
Warning Reference Low
0 N/A
All set-ups
TRUE
-3
Int32
4-55
Warning Reference High
6010 N/A
All set-ups
TRUE
-3
Int32
4-56
Warning Feedback Low
0 ProcessCtrlUnit
All set-ups
TRUE
-3
Int32
4-57
Warning Feedback High
6010 ProcessCtrlUnit
All set-ups
TRUE
-3
Int32
4-58
Missing Motor Phase Function
[1] On
All set-ups
FALSE
-
Uint8
4-6* Speed Bypass
4-61
Bypass Speed From [Hz]
0 Hz
All set-ups
TRUE
-1
Uint16
4-63
Bypass Speed To [Hz]
0 Hz
All set-ups
TRUE
-1
Uint16
5.1.7 5-** Digital In/Out
Par.
No. #
Parameter description
Default value
2-set-up
Change
during
operation
Conver-
sion index
Type
5-0* Digital I/O mode
5-00
Digital Input Mode
[0] PNP
1 set-up
FALSE
-
Uint8
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
[8] Start
All set-ups
TRUE
-
Uint8
5-11
Terminal 19 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-12
Terminal 27 Digital Input
[2] Coast inverse
All set-ups
TRUE
-
Uint8
5-13
Terminal 29 Digital Input
[12] Jog
All set-ups
TRUE
-
Uint8
5-4* Relays
5-40
Function Relay
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-41
On Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-42
Off Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-5* Pulse Input
5-50
Term. 29 Low Frequency
20 Hz
All set-ups
TRUE
0
Uint32
5-51
Term. 29 High Frequency
32000 Hz
All set-ups
TRUE
0
Uint32
5-52
Term. 29 Low Ref./Feedb. Value
0 N/A
All set-ups
TRUE
-3
Int32
5-53
Term. 29 High Ref./Feedb. Value
50
All set-ups
TRUE
-3
Int32
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
0 N/A
All set-ups
TRUE
0
Uint32
Parameter Lists
Programming Guide
MG18P202