The endpoints P1 and P2 are defined in
depending on choice of input.
Input
Analog 53
voltage mode
Analog 53
current mode
Analog 54
voltage mode
Analog 54
current mode
Pulse Input 29 Pulse Input 33
P1=(Minimum input value, Minimum reference value)
Minimum reference value
6-14 Terminal
53 Low Ref./
Feedb. Value
6-14 Terminal 53
Low Ref./Feedb.
Value
6-24 Terminal
54 Low Ref./
Feedb. Value
6-24 Terminal 54
Low Ref./Feedb.
Value
5-52 Term. 29
Low Ref./Feedb.
Value
5-57 Term. 33 Low
Ref./Feedb. Value
Minimum input value
6-10 Terminal
53 Low Voltage
[V]
6-12 Terminal 53
Low Current
[mA]
6-20 Terminal
54 Low Voltage
[V]
6-22 Terminal 54
Low Current
[mA]
5-50 Term. 29
Low Frequency
[Hz]
5-55 Term. 33 Low
Frequency
[Hz]
P2=(Maximum input value, Maximum reference value)
Maximum reference value
6-15 Terminal
53 High Ref./
Feedb. Value
6-15 Terminal 53
High Ref./Feedb.
Value
6-25 Terminal
54 High Ref./
Feedb. Value
6-25 Terminal 54
High Ref./Feedb.
Value
5-53 Term. 29
High Ref./Feedb.
Value
5-58 Term. 33 High
Ref./Feedb. Value
Maximum input value
6-11 Terminal
53 High
Voltage
[V]
6-13 Terminal 53
High Current
[mA]
6-21 Terminal
54 High
Voltage
[V]
6-23 Terminal 54
High Current
[mA]
5-51 Term. 29
High Frequency
[Hz]
5-56 Term. 33 High
Frequency
[Hz]
Table 2.3 P1 and P2 Endpoints
Product Overview
Design Guide
MG06B402
Danfoss A/S © 09/2014 All rights reserved.
25