FC 300 Operating Instructions
How to Programme
9-** Profibus
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
9-00
Setpoint
0
All set-ups
TRUE
0
Uint16
9-07
Actual Value
0
All set-ups
FALSE
0
Uint16
9-15
PCD write configuration
0
1 set-up
TRUE
-
Uint16
9-16
PCD read configuration
0
1 set-up
TRUE
-
Uint16
9-18
Node address
126
1 set-up
TRUE
0
Uint8
9-22
Telegram selection
[1] Standard telegram 1
1 set-up
TRUE
-
Uint8
9-23
Parameters for signals
0
All set-ups
TRUE
-
Uint16
9-27
Parameter edit
[1] Enabled
1 set-up
FALSE
-
Uint16
9-28
Process control
[1] Enable cyclic master
1 set-up
FALSE
-
Uint8
9-53
Profibus Warning Word
0
All set-ups
TRUE
0
V2
9-63
Actual baud rate
[255] No baudrate found
All set-ups
TRUE
-
Uint8
9-64
Device Identification
0
All set-ups
TRUE
0
Uint16
9-65
Profile number
0
All set-ups
TRUE
0
Uint8
9-67
Control word 1
0
All set-ups
TRUE
0
V2
9-68
Status word 1
0
All set-ups
TRUE
0
V2
9-71
Save Data Values
[0] Off
All set-ups
TRUE
-
Uint8
9-72
Drive Reset
[0] No action
1 set-up
FALSE
-
Uint8
9-80
Defined parameters (1)
0
All set-ups
FALSE
0
Uint16
9-81
Defined parameters (2)
0
All set-ups
FALSE
0
Uint16
9-82
Defined parameters (3)
0
All set-ups
FALSE
0
Uint16
9-83
Defined parameters (4)
0
All set-ups
FALSE
0
Uint16
9-90
Changed parameters (1)
0
All set-ups
FALSE
0
Uint16
9-91
Changed parameters (2)
0
All set-ups
FALSE
0
Uint16
9-92
Changed parameters (3)
0
All set-ups
FALSE
0
Uint16
9-93
Changed parameters (4)
0
All set-ups
FALSE
0
Uint16
10-** CAN fieldbus
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
10-0* Common settings
10-00 CAN protocol
[1] Device Net
All set-ups
FALSE
-
Uint8
10-01 Baudrate select
[20] 125 Kbps
All set-ups
FALSE
-
Uint8
10-02 MAC ID
63
All set-ups
FALSE
0
Uint8
10-05 Readout Transmit Error Counter
0
All set-ups
TRUE
0
Uint8
10-06 Readout Receive Error Counter
0
All set-ups
TRUE
0
Uint8
10-07 Readout Bus Off Counter
0
All set-ups
TRUE
0
Uint16
10-1* DeviceNet
10-10 Process data type selection
App. dependent
1 set-up
TRUE
-
Uint8
10-11 Process Data Config Write
0
All set-ups
FALSE
0
Uint8
10-12 Process Data Config Read
0
All set-ups
FALSE
0
Uint8
10-13 Warning Parameter
63
All set-ups
FALSE
0
Uint8
10-14 Net Reference
[0] Off
All set-ups
TRUE
-
Uint8
10-15 Net Control
[0] Off
All set-ups
TRUE
-
Uint8
10-2* COS filters
10-20 COS Filter 1
65535
All set-ups
FALSE
0
Uint16
10-21 COS Filter 2
65535
All set-ups
FALSE
0
Uint16
10-22 COS Filter 3
65535
All set-ups
FALSE
0
Uint16
10-23 COS Filter 4
65535
All set-ups
FALSE
0
Uint16
10-3* Parameter access
10-30 Parameter Data Types
[0] Errata 1
All set-ups
TRUE
-
Uint8
10-31 Array index
0
All set-ups
TRUE
0
Uint16
10-39 Devicenet F parameters
0
All set-ups
TRUE
0
Uint32
*
default setting
( )
display text
[ ]
value for use in communication via serial communication port
43