FC 300 Operating Instructions
How to Programme
1-** Load/Motor
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
1-0* General settings
1-00
Configuration mode
[0] Speed open loop
All set-ups
FALSE
-
Uint8
1-01
Motor control principle
[1] VVCplus
All set-ups
FALSE
-
Uint8
1-2* Motor data
1-20
Motor power [kW]
Drive dependent
All set-ups
FALSE
1
Uint32
1-22
Motor voltage
Drive dependent
All set-ups
FALSE
0
Uint16
1-23
Motor frequency
Drive dependent
All set-ups
FALSE
0
Uint16
1-24
Motor current
Drive dependent
All set-ups
FALSE
-2
Uint16
1-25
Motor nominal speed
Drive dependent
All set-ups
FALSE
67
Uint16
1-29
Automatic motor adaptation(AMA)
[0] Off
All set-ups
FALSE
-
Uint8
1-3* Advanced motor data
1-30
Stator resistance (Rs)
Motor dependent
All set-ups
FALSE
-4
Uint32
1-31
Rotor resistance (Rr)
Motor dependent
All set-ups
FALSE
-4
Uint32
1-33
Stator leakage reactance (X1)
Motor dependent
All set-ups
FALSE
-4
Uint32
1-34
Rotor leakage reactance (X2)
Motor dependent
All set-ups
FALSE
-4
Uint32
1-35
Main reactance (Xh)
Motor dependent
All set-ups
FALSE
-4
Uint32
1-36
Iron loss resistance (Rfe)
Motor dependent
All set-ups
FALSE
-3
Uint32
1-39
Motor poles
Motor dependent
All set-ups
FALSE
0
Uint8
1-5* Load indep. setting
1-50
Motor magnetizing at zero speed
100 %
All set-ups
TRUE
0
Uint16
1-51
Min speed normal magnetizing [RPM]
1 RPM
All set-ups
TRUE
67
Uint8
1-6* Load depen. setting
1-60
Low speed load compensation
100 %
All set-ups
TRUE
0
Int16
1-61
High speed load compensation
100 %
All set-ups
TRUE
0
Int16
1-62
Slip compensation
100 %
All set-ups
TRUE
0
Int16
1-63
Slip compensation time constant
0.10 s
All set-ups
TRUE
-2
Uint16
1-64
Resonance dampening
100 %
All set-ups
TRUE
0
Uint16
1-65
Resonance dampening time constant
5 ms
All set-ups
TRUE
-3
Uint8
1-66
Min. current at low speed
100 %
All set-ups
TRUE
0
Uint8
1-67
Load type
[0] Passive load
All set-ups
TRUE
-
Uint8
1-68
Minimum inertia
Drive dependent
All set-ups
FALSE
-4
Uint32
1-69
Maximum inertia
Drive dependent
All set-ups
FALSE
-4
Uint32
1-7* Start adjustments
1-71
Start delay
0.0 s
All set-ups
TRUE
-1
Uint8
1-72
Start function
[2] Coast/delay time
All set-ups
TRUE
-
Uint8
1-74
Start speed [RPM]
0 RPM
All set-ups
TRUE
67
Uint16
1-76
Start current
0.00 A
All set-ups
TRUE
-2
Uint16
1-8* Stop adjustments
1-80
Function at stop
[0] Coast
All set-ups
TRUE
-
Uint8
1-81
Min speed for function at stop [RPM]
0 RPM
All set-ups
TRUE
67
Uint16
1-9* Motor temperature
1-90
Motor thermal protection
[0] No protection
All set-ups
TRUE
-
Uint8
1-91
Motor external fan
[0] No
All set-ups
TRUE
-
Uint16
1-93
Thermistor source
[0] None
All set-ups
FALSE
-
Uint8
*
default setting
( )
display text
[ ]
value for use in communication via serial communication port
36
MG.33.A2.02 - VLT is a registered Danfoss trademark