10.1.1 Mains Supply 1 x 200 - 240V AC
Mains
Supply
1
x
200
-
240V
AC
-
Normal
overload
110%
for
1
minute
Frequency
converter
Typical
Shaft
Output
[kW]
P1K1
1.1
P1K5
1.5
P2K2
2.2
P3K0
3.0
P3K7
3.7
P5K5
5.5
P7K5
7.5
P15K
15
P22K
22
Typical
Shaft
Output
[HP]
at
240V
1.5
2.0
2.9
4.0
4.9
7.5
10
20
30
IP20
/
Chassis
A3
-
-
-
-
-
-
-
-
IP21
/
NEMA
1
-
B1
B1
B1
B1
B1
B2
C1
C2
IP55
/
NEMA
12
A5
B1
B1
B1
B1
B1
B2
C1
C2
IP66
A5
B1
B1
B1
B1
B1
B2
C1
C2
Output
current
130BA058.10
Continuous
(3
x
200-240V)
[A]
6.6
7.5
10.6
12.5
16.7
24.2
30.8
59.4
88
Intermittent
(3
x
200-240V)
[A]
7.3
8.3
11.7
13.8
18.4
26.6
33.4
65.3
96.8
Continuous
kVA
(208V
AC)
[kVA]
5.00
6.40
12.27
18.30
Max.
cable
size:
(mains,
motor,
brake)
[[mm
2
/
AWG]
2)
0.2-4
/
4-10
10/7
35/2
50/1/0
95/4/0
Max.
input
current
130BA057.10
Continuous
(1
x
200-240V)
[A]
12.5
15
20.5
24
32
46
59
111
172
Intermittent
(1
x
200-240V)
[A]
13.8
16.5
22.6
26.4
35.2
50.6
64.9
122.1
189.2
Max.
pre-fuses
1)
[A]
20
30
40
40
60
80
100
150
200
Environment
Estimated
power
loss
at
rated
max.
load
[W]
4)
44
30
44
60
74
110
150
300
440
Weight
enclosure
IP20
[kg]
4.9
-
-
-
-
-
-
-
-
Weight
enclosure
IP21
[kg]
-
23
23
23
23
23
27
45
65
Weight
enclosure
IP55
[kg]
-
23
23
23
23
23
27
45
65
Weight
enclosure
IP66
[kg]
-
23
23
23
23
23
27
45
65
Efficiency
3)
0.968
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
Table
10.1
Mains
Supply
1
x
200
-
240V
AC
-
Normal
Overload
110%
for
1
Minute
Specifications
VLT
®
AQUA Drive
Operating Instructions
MG.20.M8.02 - VLT
®
is a registered Danfoss trademark
67
10
10