6 CAN Type and Other Fieldbus Option Boards
6.1 The OPTE6 and OPTE7 Option Boards
6.1.1 The OPTE6 and OPTE7 Option Board Layout
The OPTE6 and OPTE7 option boards have two different hardware revisions with slightly different layout. The layout is different in
the LED arrangement and termination resistor orientation. The two hardware revisions are marked with different product codes.
The product code is marked in the sticker on top of the option board.
The hardware versions are listed in the following table.
Table 12: Hardware Versions
Board
In production starting from 2017
Not in production
OPTE6
70CVB01605 (141X4171)
70CVB01124 (141X3915)
OPTE7
70CVB01817 (141X4403)
70CVB01555 (141X4133)
pr
od
uc
t c
od
e
serial no.
M/N
A
N/M
e3
0b
i0
88
.1
0
Illustration 30: The OPTE6 and OPTE7 Option Board Layout Combining the Old and New Hardware Versions
OPTE6 and OPTE7 have one difference in signals. In OPTE7, communication power supply is connected to pin 5. OPTE6 has no con-
nection.
Table 13: The Connections of the Option Board
Signal
Connector pin Screw plug OPTE3,
OPTE2
Sub-D9 OPTE5, OPTE8 Description
V-
1
1
CAN bus GND V- isolated digital ground reference
CAN LO 2
2
CAN bus LO
Shield
3
3
Shield connector
CAN HI
4
4
CAN bus HI
V+
N/A
5
V+ (24 V) for DeviceNet. Not connected for CANopen.
6.1.2 The Jumpers in the OPTE6 and OPTE7 Option Boards
The locations of the termination resistor jumpers depend on the hardware version, see
.
AN338644703080en-0002 / DPD02156
48 | Danfoss A/S © 2022.08
CAN Type and Other Fieldbus
Option Boards
VACON® RS485 and CAN Bus Option Boards
Installation Guide
Содержание VACON OPTE3