Po Polsku Specyfikacja
(GB) Mounting / (F) Montage / (DK) Montering / (ES) Montaje / (D) Befestigung / (NL) Montage / (PL) Zamocowanie
Ważna uwaga RF
: Należy sprawdzić, aby w
prostej linii między termostatem i nadajnikiem
nie znajdowały się duże metalowe przedmioty,
takie jak bojlery lub inne duże urządzenia,
gdyż mogą one uniemożliwić łączność między
termostatem i nadajnikiem.
(GB) Wiring (hard-wired versions only) / (F) Câblage (versions câblées uniquement) / (DK) Ledningsføring (ledningstrukne
versioner) / (ES) Cableado (solo versiones de conexión permanente / (D) Verkabelung (nur bei Kabelversion) / (NL) Bedrading (alleen
uitvoeringen met kabelaansluiting) /
(PL) Podłączanie przewodów (tylko dla wersji podłączanych na stałe)
(GB) Connections / (F) Connexions / (DK) Opkoblinger / (ES) Conexiones / (D) Anschlüsse
/ (NL) Aansluitingen (PL)
TP7000
TP7000M
Thermostat Features
Order code - Built-in sensor model
087N741000
087N741400
087N740000
087N740400
087N740800
087N741900
- Remote sensor model, (A models)
087N741100
087N741500
087N740100
087N740500
087N740900
087N742000
Control type - On/Off or chrono- proportional, 3/6
cycles per hour
l
l
l
Control type - On/Off or chrono- proportional, 6/12
cycles per hour, (C models)
l
l
l
RF - wireless thermostat
Hardwired thermostat
Digital clock type
Selectable 7-day or 5/2-day operation
Number of events per day
Control temperature range
Total switching differential (On/off mode)
Factory pre-set programme
Programmable holiday mode
Installer selectable Optimum start control
Themostat mode and frost mode
Power supply
Memory backup
Switching action of output relay
Switch rating of relay contact, voltage and current
Transmitter frequency (RF models only)
Transmitter range (RF models only)
Dimensions (mm)
Pollution Situation
Rated Impulse Voltage
Ball Pressure Test
l
l
l
Note 1): Unit must powered up for 6 days to charge cell before full back-up is available
Rechargable cell
(see note 1)
Capacitor during battery change for I minute
N/A
N/A
3(1) A, 230 volts
SPST
433.92 MHz
30 meters max.
N/A
230v, 50 Hz
2 x AA/MN1500/LR6 alkaline batteries
Yes, up to 99 days
Yes, set to 1.0°C, but adjustable between 5 - 30°C
24 hour, (can set to AM/PM mode by user)
Yes
Yes
Yes - Off, 30, 60, 90 or 120 minutes early switch on at set-point minus 4K
Up to 6
Off, 5 - 30°C, (can be set to Fahrenheit by user)
<1.0°C
TP7000-RF
TP7000
TP7000M
75°C
N/A
2.5Kv
N/A
138 wide x 88 high x 28 deep
Degree 2
1
2
3
4
5
6
7
ELECTRONICS
REMOTE
START-UP
REMOTE
SENSOR
'B' models
only
'A' models
only
LOAD
TP7000-RF
1
2
3
4
5
6
7
ELECTRONICS
REMOTE
START-UP
REMOTE
SENSOR
'B' models
only
'A' models
only
LOAD
N
L
230Vac
1
2
3
4
5
6
7
ELECTRONICS
REMOTE
SENSOR
'A' models
only