Service Manual and
Axial Piston Pumps Series 20
Repair Instructions
L1003506
• Rev BA • Jun 2014
15
1. Disconnect the external control linkage from
the control handle and check for neutral
operating with control handle. Releasing
control handle should allow the pump to
return to neutral. If operation is satis factory
with external control linkage disconnected,
the problem is not in the hydrostatic
transmission.
If operation is not satisfactory with external
control linkage disconnec ted from control
handle, the control may be misadjusted.
3. Holding the control in place, and swing it
away from housing and remove. Inspect
visible linkages, tor sion spring, and O-rings.
Inspect for missing, plugged, or incorrect
orifice.
Checking the servo valve (control valve)
Trouble Shooting
2. Remove the cap screws (see
page 22
).
4. Further disassembly of servo valve is not
permitted.
Inspection Instructions
(continued)
F000 082
F000 083
F000 046
F000 062
86
89, 90
82
86
78
Orifice (81)
81 85 80 86 87 88