7 DAYS PROGRAMMING ( -T74 ) 

 7 days four events programming: four events each day (1, 2, 3, 4), there is starting time and programming temp for 

each event. (chart.1) 

Please make good plan of starting time and temp. Before 7 days programming according below: 

 Press “

” for 3 seconds, until “PROG.”, “1” and “Mon” display, set 4 events programming of Mon according Chart 1 

and below steps. 

“hh” flash in “hh:mm”, set hours with “

” and “

”; Press “

”, “mm” flash in “hh:mm”, press “

” and “

”to set minutes. 

Press “

”, programming temp. flash, press “

” or “

” to set programming temp. 

Press “

”, set 2 - 4 events of Mon. by repeating steps above.   

 

 

Chart 

Week 

Staring T / temp.

 

Staring T / temp.

 ℃

 

Staring T / temp.

 ℃

 

Staring T / temp.

 ℃

 

Mon. 

7:00          25

 

8:00          25

 

18:00          25

 

21:00          25

 

Tue. 

7:00          25

 

8:00          25

 

18:00          25

 

21:00          25

 

Wed. 

7:00          25

 

8:00          25

 

18:00          25

 

21:00          25

 

Thu. 

7:00          25

 

8:00          25

 

18:00          25

 

21:00          25

 

Fri. 

7:00          25

 

8:00          25

 

18:00          25

 

21:00          25

 

Sat. 

7:00          25

 

8:00          25

 

18:00          25

 

21:00          25

 

Sun. 

7:00          25

 

8:00          25

 

18:00          25

 

21:00          25

 

Repeat above setting steps for “Tue Wed Thu Fri Sat Sun”. 

KEYPAD LOCK ( Option ) 

 

 With thermostat standby for 30 seconds, the function will enable automatically. The "

" will be displayed on the 

LCD and keypads are locked for fear anyone operated. 

 To disable the function: Press “

” button for 5 seconds till "

" disappeared on the LCD, the function will be disable. 

AUTO RESTART ( Option ) 

 When the thermostat is at ON status for 6 seconds, if power cut, it will return back to running automatically with the 

status how it is one minute ago after power coming back. 

 When the thermostat is at OFF status for 6 seconds, if power cut, it will keep OFF status after power coming back. 

DEFROST (Low temperature protection) 

 Description: when the thermostat turns off and the room temperature is lower than 5 , it will be turned on 

automatically in heating mode with “

” showing, thermostat will be in heat mode and fan runs in high speed. The 

thermostat will turn off when temperature is higher than 7

 Set low temperature protection: Turn off the thermostat, press “ ” and hold for 3 seconds, it will display “ON” or 

“OF”, Press “

” or “

” key to adjust. “OF” indicates invalid low temperature protection, “ON“ indicates valid low 

temperature protection function. The default is “OF”. 

ALARM 

 

Trouble appears for sensor, fan and valve will be turned off by thermostat, as indicating “ ” 

and “E1” or “E2”.   

E1: alarming for short circuit of sensor.E2: alarming for open circuit of sensor. 

“HI” indicated when temp. Is more than 55 . “LO” indicated if temp. Is lower than 0 .   

 

 

Содержание RESD Series

Страница 1: ...tatus Cool Heat Ventilation Fan Speeds Low Medium High and Auto Room temperature display Temperature setting display FCU valve Clock week display SPECIFICATIONS Sensing element NTC Accuracy Temperature 1 C Time 1 min month Set point range 5 to 35 C Display range 0 to 55 C Operation environment T min 0 C T max 45 C Power supply 85 to 260V 50 60Hz Switch current rating Resistive 2 A Inductive 1 A Sw...

Страница 2: ...en room temperature and setting temperature exceed 1 C Auto MED speed When exceed CAuto HI speed When e xceed 3 C CLOCK CALIBRATION Clock setting Press till to display hh mm and hh flash press or to adjust hour press mm flash press or to adjust minute Press week flash press or to adjust Mon to Sun TIMER ON AND TIMER OFF Timer on Press till to display and ON and all flash and also hh flash press or...

Страница 3: ...n the LCD and keypads are locked for fear anyone operated To disable the function Press button for 5 seconds till disappeared on the LCD the function will be disable AUTO RESTART Option When the thermostat is at ON status for 6 seconds if power cut it will return back to running automatically with the status how it is one minute ago after power coming back When the thermostat is at OFF status for ...

Страница 4: ...electrical box is required Wiring work should be done according to wiring diagram Water mud etc impurity should be kept outside of thermostat or damage will occur 1 Open the clip 2 Wiring 3 Fix thermostat with two bolts 4 Lock surface and finished ...

Отзывы: