manualshive.com logo in svg
background image

In this chapter, you will find important information on how to avoid life-threatening situations and
injuries and how to prevent product damage.

General information

These instructions are part of the device.

They contain text and illustrations for the correct handling of the module and must be read before
installation or use.

Before deploying the device described in this document, read the entire Technical Information and the
User Manual document, including all safety information.

Non-observance of the notes, operation that is not in accordance with use as prescribed below, wrong
installation or handling can result in serious harm concerning the safety of people and plant.

Keep this manual for future use and make all information available to anyone deploying the device, even
after installation.

Tampering with the device can lead to considerable risks for the safety of people and plant. It is not
permitted and leads to an exclusion of any liability and warranty claims.

The device must be installed, connected and put into operation by a qualified electrician.

In the event of malfunctions or uncertainties, please contact the manufacturer.

This device is designed to be used in systems which must be checked for conformity with legal
requirements prior to placing into operation. The integrator of this device is responsible to check and
comply with regional directives and requirements.

W

Warning

Danfoss strongly recommends that initialization and provisioning of CS500 IoT Gateways be completed

outside of machine production processes. It is best practice to de-couple this initialization and

provisioning from machine production processes.

Safety advice

General

Danger due to possibly deficient data transmission.

CS500 unit operates using radio signals and cellular networks and is not authorized for use in safety-
related applications.

Deficient network coverage, failure or malfunction of the device may lead to deficient data transmission.
Because of this, connection cannot be guaranteed at all times under all conditions.

Do not operate the device in machines and applications where life depends on the proper operation
of this piece of equipment.

Never rely solely upon any wireless device for essential communications.

Health care

Danger of interference caused by RF energy.

Medical equipment may be sensitive to RF energy.

Technical Information

PLUS+1® Connect CS500 IoT Gateway

Safety information

 

10 | 

©

 Danfoss | October 2021

BC397226723595en-000101en-000101

Содержание PLUS+1 Connect CS500

Страница 1: ...Technical Information PLUS 1 Connect CS500 IoT Gateway www danfoss com...

Страница 2: ...Revision history Table of revisions Date Changed Rev October 2021 First edition 0101 Technical Information PLUS 1 Connect CS500 IoT Gateway 2 Danfoss October 2021 BC397226723595en 000101en 000101...

Страница 3: ...100 12 Ordering information Related products 13 Device functions Operations 14 GNSS Global Navigation Satellite System 14 Wireless Solution 14 SIM card 14 Input output functions I O 14 CAN interfaces...

Страница 4: ...CS500 Dimensions 22 Mounting Technical Information PLUS 1 Connect CS500 IoT Gateway Contents 4 Danfoss October 2021 BC397226723595en 000101en 000101...

Страница 5: ...s with components of other manufacturers CS500 literature references Reference literature Literature title Literature type Literature number PLUS 1 Connect CS500 Technical Information PLUS 1 Connect C...

Страница 6: ...low 1 Mounting Holes 2 GPS connector 3 Cellular 4G connector 4 LEDs 5 Power CAN MFIO connector 6 Label Type label The CS500 type label is located on the side of the enclosure CS500 type label informat...

Страница 7: ...rrectly mounted or maintained equipment Danfoss does not assume any responsibility for PLUS 1 products being incorrectly applied or the system being programmed in a manner that jeopardizes safety All...

Страница 8: ...will be voided if device is opened Device is not field serviceable Do not open the device Technical Information PLUS 1 Connect CS500 IoT Gateway Device Elements 8 Danfoss October 2021 BC397226723595e...

Страница 9: ...0R 06 11848 PTCRB This device has been certified for use on PTCRB Mobile Network Operator networks For more information see the certified device section http ptcrb com PLUS 1 Compliance Danfoss CS100...

Страница 10: ...anufacturer This device is designed to be used in systems which must be checked for conformity with legal requirements prior to placing into operation The integrator of this device is responsible to c...

Страница 11: ...tions fuel depots chemical plants or where blasting operations are in progress Do not mount the antenna in the close environment of fuel tanks vessels with explosives and insufficiently shielded elect...

Страница 12: ...e installation of the control system The following is recommended when welding on a machine equipped with electronic components Turn the engine off Remove electronic components from the machine before...

Страница 13: ...500 IoT Gateway and Antenna Kit 11247193 Replacement CS500 IoT Gateway 11247192 Replacement Antenna 11247194 DEUTSCH mating connector bag assembly 10102025 16 to 20 AWG 10100944 20 to 24 AWG Technical...

Страница 14: ...and Galileo satellites It can process data from multiple navigation systems simultaneously this increases the accuracy The CS500 uses GNSS as a time source When GNSS sync is not available the local ti...

Страница 15: ...nnect portal PLUS 1 Service Tool or programmatically with PLUS 1 GUIDE to monitor the machine state performance and position Both position and machine data are periodically transmitted and stored to t...

Страница 16: ...e where it is level with the local geographic horizon and has full view of the sky above Power Supply CAN Bus I O Connector 1 Pin Designation Description 1 Ground Power supply 2 9 to 36 VDC Power supp...

Страница 17: ...Certification Interface Protocol Certification CAN bus network 2 ISO 11898 2 High Speed 2 0A B Multifunction Input 2 DIN AIN ResIN FreqIN CrntIN CL15 DOUT Radio Module Cat 1 TE with 3G Fallback Cat 1...

Страница 18: ...7 V Frequency input middle range Description Unit Minimum Typical Maximum Comment Range Hz 0 10000 In steps of 1 Hz Range phase and quad Hz 0 5000 In steps of 1 Hz Rising voltage threshold V 3 89 Volt...

Страница 19: ...32 1 32 1 33 Input impedance to 5V Outputs Digital output Description Unit Minimum Maximum Comment Output Voltage range V 0 36 Current mA 0 3000 Do not connect a digital output to battery back drive...

Страница 20: ...D light correct sequence The LED lights up green constantly during the first second The LED starts to flash Problem with connection to PLUS 1 Connect portal After connecting to power supply the LED sh...

Страница 21: ...operate the device unless temperature is between 40 C and 75 C 40 F and 167 F Do not store and or transport the device unless it is kept at a temperature between 40 C and 85 C 40 F and 185 F Disposal...

Страница 22: ...CS500 Dimensions Technical Information PLUS 1 Connect CS500 IoT Gateway CS500 Technical Drawings 22 Danfoss October 2021 BC397226723595en 000101en 000101...

Страница 23: ...ector wires Antenna must be mounted on external surface with a view to the sky C Caution Device damage may occur Use caution when installing CS500 Due to the size of the mating connector wire bundle i...

Страница 24: ...Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New District Sha...

Отзывы: