Instruction
Pump instruction PAHT C 2-6.3
34
180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022
2.2 Open-system design
A
Inlet line:
Dimension the inlet line to obtain mini-
mum pressure loss (large flow, minimum
pipe length, minimum number of bends/
connections, fittings with small pressure
losses and restrictions) .
B
Inlet filter:
Install the inlet filter (1) in front of the PAHT
pump (2) . Please consult the Danfoss filter
data sheet for guidance on how to select
the right filter .
C
Monitoring pressure switch:
Install the monitoring pressure switch (3)
between the filter and the pump inlet . Set
the minimum inlet pressure according to
specifications described in item 4, technical
data . The monitoring pressure switch stops
the pump if inlet pressure is lower than the
set minimum pressure .
D
Monitoring temperature switch:
Install the monitoring temperature switch
(4) between the filter and the pump, on
either side of the monitoring pressure
switch . Set the temperature value accord-
ing to technical data, item 4 . The monitor-
ing temperature switch stops the pump if
inlet temperature is higher than the set
value .
E
Hoses:
Always use flexible hoses (5) to minimize
vibrations and noise .
F
Inlet pressure:
In order to eliminate the risk of cavitation
and other pump damage, pump inlet
pressure must be maintained according to
specifications described in item 4, technical
data .
G
Non-return valve (6):
Should be installed after the outlet to
prevent pump backspin, which may ruin
the pump .
H
Pressure relief valve:
As the Danfoss PAHT pump begins to
create pressure and flow immediately after
start-up regardless of any counter pressure,
a pressure relief valve (7) should be
installed to prevent system damage .
I
Drain:
Always install a proper drain (8) in order to
safely drain the fluid to avoid
vaporization and to ensure a safe drain,
without human contact before inspection
and/or service .
Note: If a non-return valve is mounted in the
inlet line, a low-pressure relief valve is also
recommended between the non-return valve
and the pump to protect against high-pressure
peaks.
PI
System
PI
M
1
2
3
4
5
5
7
8
6
Содержание PAHT C
Страница 30: ...Danfoss DCS im 2017 06 521B1374 A 234386502982en000401 PAHT C pumps UK 06 2017 30...
Страница 41: ...Instruction Pump instruction PAHT C 2 6 3 41 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 01 2022...
Страница 46: ...46 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 01 2022...
Страница 49: ...hpp danfoss com Parts list PAHT C 2 6 3 pumps Parts list PAHT C pumps PAHT C 2 3 2 4 6 3 hpp danfoss com...
Страница 68: ...Danfoss A S High Pressure Pump Nordborgvej 81 DK 6430 Nordborg Denmark Danfoss DCS im 11 2016 11 2016 68...
Страница 75: ...180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 75 Danfoss DCS im 2022 01...
Страница 76: ...Danfoss DCS im 2022 01 76 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps...