Instruction
Pump instruction PAHT C 2-6.3
33
180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022
2.1 Closed-system design
A
Inlet line:
Dimension the inlet line to obtain mini-
mum pressure loss (large flow, minimum
pipe length, minimum number of bends/
connections, fittings with small pressure
losses and restrictions) .
B
Inlet filter:
Install the filter (1) in front of the tank (2) .
Please consult the Danfoss filter data sheet
for guidance on how to select the right
filter .
C
Monitoring pressure switch:
Install the monitoring pressure switch (3) in
front of the filter (1) . Set the maximum inlet
pressure to 2 barg (29 .0 psig) . The monitor-
ing pressure switch will stop the pump (5) if
inlet pressure is higher than 2 barg (29 .0
psig), indicating that the filter element
must be changed .
D
Monitoring temperature switch:
Install the monitoring temperature switch
(4) in the tank . Set the temperature value
according to technical data, item 4 . The
monitoring temperature stops the pump if
inlet temperature is higher than the set
value .
E
Hoses:
Always use flexible hoses (6) to minimize
vibrations and noise .
F
Inlet pressure:
In order to eliminate the risk of cavitation
and other pump damage, pump inlet
pressure must be maintained according to
specifications described in item 4, technical
data .
G
Non-return valve (7):
Should be installed after the outlet to
prevent pump backspin, which may ruin
the pump .
H
Pressure relief valve:
As the Danfoss PAHT pump begins to
create pressure and flow immediately after
start-up regardless of any counter pressure,
a pressure relief valve (8) should be
installed to prevent system damage .
I
System water filling:
To ensure proper filtration of new water
(10) supplied to the system, always use the
filling valve (9) .
J
Minimum level switch:
Install the minimum level switch (11) above
the outlet of the reservoir . The level switch
must stop the pump if the water in the
reservoir is below the switch, which
indicates that the reservoir is empty .
K
Drain:
Always install a proper drain (12) in order
to safely drain the fluid to avoid
vaporization and to ensure a safe drain,
without human contact before inspection
and/or service .
Reservoir
PI
System
PI
M
1
2
3
4
6
6
7
8
5
9
12
10
11
2.
System design
Содержание PAHT C
Страница 30: ...Danfoss DCS im 2017 06 521B1374 A 234386502982en000401 PAHT C pumps UK 06 2017 30...
Страница 41: ...Instruction Pump instruction PAHT C 2 6 3 41 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 01 2022...
Страница 46: ...46 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 01 2022...
Страница 49: ...hpp danfoss com Parts list PAHT C 2 6 3 pumps Parts list PAHT C pumps PAHT C 2 3 2 4 6 3 hpp danfoss com...
Страница 68: ...Danfoss A S High Pressure Pump Nordborgvej 81 DK 6430 Nordborg Denmark Danfoss DCS im 11 2016 11 2016 68...
Страница 75: ...180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 75 Danfoss DCS im 2022 01...
Страница 76: ...Danfoss DCS im 2022 01 76 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps...