background image

User Manual

PLUS+1® Compliant OX024-x10 Function Block

 

14 | 

©

 Danfoss | July 2018

11063395 | AQ00000104en-US0101

Содержание OX024-x10

Страница 1: ...User Manual PLUS 1 Compliant OX024 x10 Function Block www danfoss com...

Страница 2: ...Revision history Table of revisions Date Changed Rev July 2018 Rebranding 0101 July 2016 BA User Manual PLUS 1 Compliant OX024 x10 Function Block 2 Danfoss July 2018 11063395 AQ00000104en US0101...

Страница 3: ...ts 7 Inputs CAN 8 Connections and Signal Overview 9 Configure Communications Between Controller and I O Module 10 Variable Addressing Mode 10 Predefined Addressing Mode 10 Fixed Addressing Mode 11 Vol...

Страница 4: ...g Tx ID and Rx ID The CAN messages use either 11 bit or 29 bit identifiers in this mode as determined by Frame Tx ID U32 0x00 0x1FFFFFFF Tx ID is the CAN message identifier used by the function block...

Страница 5: ...n the Output values are transmitted to the I O module 1000 is 1 ms TimeOut_Outputs U16 0 65535 Sets the maximum time allowed between commands for each output If a command is not received by the I O mo...

Страница 6: ...Out True Updated BOOL Input True when the Volt and PinStatus signals are refreshed Inputs MFOut Output Status The input status of multifunction outputs on connectors and pins C1p12 C2p01 C2p02 C2p03 C...

Страница 7: ..._MFOut Bus Config Bus PinConfig U16 Output 0 8 Output pin configuration 0 Digital Output Push Pull 1 Digital Output Sourcing 2 Digital Output Sinking 3 PWM Output 0 10000 0 01 positive duty 4 PWM Outp...

Страница 8: ...ckCRC 6 Waiting for CRC response Outputs are disabled except for RecheckCRC 7 The I O module is properly configured and in the normal operational state Outputs are enabled 8 The function block s outpu...

Страница 9: ...is used in an application each block requires unique Inputs and Outputs bus connections For example IO_Bus IO_Bus1 IO_Bus2 are needed User Manual PLUS 1 Compliant OX024 x10 Function Block OX024 x10 Fu...

Страница 10: ...de must be set to 0 Every time the device is powered the CAN shield input voltage must be within the same N1 range for the function block and device to reach the Configured status After the device is...

Страница 11: ...ns are sent CAN Bus Load Adjust the average amount of message transmissions on the CAN bus to allow for bursts and other increased message transmission situations Any CAN bus has a maximum message tra...

Страница 12: ...e the proper addressing mode and corresponding communication parameters are set on both the I O module and the function block It is possible the I O module is correctly configured but a second I O mod...

Страница 13: ...User Manual PLUS 1 Compliant OX024 x10 Function Block Danfoss July 2018 11063395 AQ00000104en US0101 13...

Страница 14: ...User Manual PLUS 1 Compliant OX024 x10 Function Block 14 Danfoss July 2018 11063395 AQ00000104en US0101...

Страница 15: ...User Manual PLUS 1 Compliant OX024 x10 Function Block Danfoss July 2018 11063395 AQ00000104en US0101 15...

Страница 16: ...lutions ApS Nordborgvej 81 DK 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading S...

Отзывы: