3. Remove stop (27) from directional spool (25).
Removing end cover at LS-connection
1.
Unscrew screws (8x81) with spring washer (8x80) using a 13 mm
socket spanner and screw (83)
with spring washer (83) using a 10 mm
Hex key.
2. Remove end cover (65).
Spring stops (10 and 30) and springs (28 and 29) will follow the end cover.
Service Manual
OSQA/OSQB
Disassembly
©
Danfoss | July 2016
HN25D293 | AX00000127en-US0101 | 13