3. Take out ball (48) using a magnetic rod.
4. Take out the piston (46) using a hook.
5. Take out the spring (45) using a hook.
Dismantled counter pressure valve
Service Manual
OSQA/OSQB
Disassembly
10 |
©
Danfoss | July 2016
HN25D293 | AX00000127en-US0101