Room Temperature Setting 10 – 30°C

: Set dial to required room 

temperature, domestic hot water store in boiler is kept hot*.

Holiday Setting 

 

: Controls room temperature at 8°C, (frost 

setting), domestic hot water store in boiler is turned off.

*(This feature is dependant upon boiler type).

Indication 

Start-Up

: When boiler is first turned on the LED will flash for 20 

seconds.

Normal Operation

: LED will be lit whenever the boiler is firing.

Holiday Mode

: When thermostat is put into, or taken out of holiday 

setting the LED will flash for 20 seconds.

 

Alarm Mode

: Should a fault occur with the boiler the LED will flash 

continuously to warn of failure.

Settings

U

ser I

nstr

uc

tions

NL

NL

GB

Содержание ORT-01

Страница 1: ...Danfoss Heating ORT 01 Electronic modulating room thermostat for OpenTherm appliances Installation and User Guide ...

Страница 2: ... installation 5 Wiring 6 7 Mounting 8 Locking Limiting 9 User Instructions 10 11 Index Index GB Technische Specificaties 12 13 Positionering Installatie 14 Bedrading 15 16 Montage 17 Blokkeren Begrenzen 18 Gebruikers handleiding 19 20 NL ...

Страница 3: ... 3 Domestic hot water keep hot feature Holiday mode ID 14 low load control Thermostat output Data Construction EN60730 2 9 IP rating IP20 Supply voltage 24V DC from boiler Wiring non polarised 2 wire bus Control pollution situation Degree 2 Ball hardness test 75 C Dimensions mm 86 high x 85 wide x 42 deep Specification Specification NL NL GB ...

Страница 4: ...lling obligation is applicable from 26th September 2015 ErP Class Product Function and ErP Description Additional efficiency gain V Modulating Room Thermostat for use with modulating heaters An electronic room thermostat that varies the flow temperature of the water leaving the heater dependent upon measured room temperature deviation from room thermostat set point Control is achieved by modulatin...

Страница 5: ...5 5FT ORT 01 Positioning and Installation Positioning and Installation NL NL GB ...

Страница 6: ...6 Wiring Wiring NL NL GB For surface mounted wiring cutouts are provided on the backplate to enable correct positioning of the cable For recessed wiring cabling can be connected as in diagram 2 1 2 ...

Страница 7: ...ortant To avoid damage to Boiler and Thermostat connect only to OpenTherm connections on boiler do not connect to any other power source A B O O OpenTherm connections in ORT 01 Wires can be crossed OpenTherm connections in boiler ...

Страница 8: ...8 Mounting Mounting NL NL GB ...

Страница 9: ...oving dial turn until setting 10 aligns with reference mark on front case 2 Remove dial lock or limit as required see note below 3 Replace dial ensuring setting 10 aligns with reference mark on case Important Note If Holiday Function is required DO NOT adjust lower limit ...

Страница 10: ...Daily use is as easy as setting the thermostat dial to the required setting the advanced electronics and software within the thermostat establish two way communication with the Opentherm boiler to ensure optimal operation In addition to the room temperature control the ORT 01 also incorporates a feature which dependant on boiler type allows the domestic hot water store in the boiler to be kept hot...

Страница 11: ...f This feature is dependant upon boiler type Indication Start Up When boiler is first turned on the LED will flash for 20 seconds Normal Operation LED will be lit whenever the boiler is firing HolidayMode When thermostat is put into or taken out of holiday setting the LED will flash for 20 seconds Alarm Mode Should a fault occur with the boiler the LED will flash continuously to warn of failure Se...

Страница 12: ...ater Comfort functie Warm tapwater Eco functie vakantie stand ID 14 regeling lage belasting Thermostaat output OpenTherm Data Fabrikagenorm EN60730 2 9 Dichtheidsklasse IP20 Voedingsspanning 24V dc van ketel Aansluiting 2 draads polariteit ongevoelig Emissiewaarde Niveau 2 Afmetingen in mm bxhxd 85x86x42 Technische Specificaties Technische Specificaties NL NL NL ...

Страница 13: ... ErP labelverplichting gaat in op 26 september 2015 ErP klasse Productfunctie en ErP beschrijving Extra rendement V Modulerende kamerthermostaat voor gebruik met modulerende verwarmingen Een elektronische kamerthermostaat die de stromingstemperatuur van het water vanuit de verwarming varieert op basis van de gemeten afwijking van de kamer temperatuur ten opzichte van het setpoint van de kamertherm...

Страница 14: ...14 Positionering Installatie Positionering Installatie NL NL NL 5FT ORT 01 ...

Страница 15: ...5 Bedrading Bedrading NL NL NL For surface mounted wiring cutouts are provided on the backplate to enable correct positioning of the cable For recessed wiring cabling can be connected as in diagram 2 1 2 ...

Страница 16: ...ermostaat alleen op de OpenTherm aansluiting van de ketel te worden aangesloten A B O O OpenTherm connections in ORT 01 Wires can be crossed OpenTherm connections in boiler Bedrading NL NL NL OpenTherm aansluiting in ORT 01 Draden mogen gewisseld worden OpenTherm aansluiting in ketel ...

Страница 17: ...17 Montage Montage NL NL NL ...

Страница 18: ... NL NL 1 2 1 Draai de instelknop op stand 10 2 Verwijder de instelknop en blokkeer of begrens naar behoefte zie onderstaand schema 3 Plaats de instelknop op stand 10 weer terug Let op Stel geen minimum begrenzing in als de Vakantie Stand nodig is ...

Страница 19: ...aatsimpelweg op de gewenste temperatuur in te stellen De geavanceerde elektronika en innovatieve software in de thermostaat verzorgen de twee weg communicatie met de OpenTherm ketel en verzekeren een optimale werking Naast de nauwkeurige ruimtetemperatuurregeling voorziet de ORT 01 ook in de funktie afhankelijk van het type ketel om de warme tapwatervoorraad op temperatuur te houden comfort of uit...

Страница 20: ...k van het keteltype LED indicator Opstarten Na het inschakelen van de voedingsspanning van de ketel knippert de LED gedurende 20 seconden Normaal bedrijf LED is aan wanneer de ketel brandt Vakantiestand Wanneer de thermostaat op Vakantiestand wordt gezet knippert de LED twee keer bij terugzetten op normaal bedrijf een keer Alarm funktie Indien zich een fout in de ketel voordoet zal de LED als waar...

Страница 21: ...21 ...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ...24 Part No 25219 Issue 4 06 2015 VIRLA14L www heating danfoss co uk ...

Отзывы: