Instructions

filter dryer replacements until the system is clean 

and acid-free.When there is no longer any sign 

of acidity, replace the anti-acid cartridges by the 

standard model and remove the suction strainer 

cartridge as required

14 - User advisory

Insist that all service operations only be per-

formed by qualified personnel.

 The condensing unit tubing and compressor 

surface temperatures may exceed 100°C (212°F) 

and cause severe bodily burns. Special precau-

tion must be taken when working around the 

compressor and refrigerant tubing. Moreover, a 

compressor in operation can generate very cold 

surface temperatures (as low as -45°C / -49°F), 

there by exposing personnel to the risk of free-

zing burns. 

 Pressure inside the compressor and refrige-

rant circuit can reach dangerously high levels 

(e.g. abnormal operation, fire,…) leading to 

personnel injury if suddenly released; therefore, 

never drill, weld or cut the compressor shell and 

adjacent tubing (release of liquid refrigerant can 

cause flash freezing on exposed skin). 

 Even though fans are fitted with safety guard 

it is recommended not to work on condenser 

while fans are running.

Be aware that the product warranty may be 

deemed null and void in the following cases:

• Modifications to the unit, unless approved by 

Danfoss Commercial Compressors, absence 

of nameplate, broken or dented components, 

shock marks, etc...

• Compressor opened by the customer or re-

turned unsealed (i.e. open discharge or suction 

ports), 

• Presence of rust or water inside the condensing 

unit circuit, 

• Addition of leak-detection fluid in the compres-

sor lubricant,

• Use of a refrigerant or lubricant not approved 

by Danfoss Commercial Compressors.,

• Any deviation from recommended instructions-

pertaining to installation, application or mainte-

nance,

• Use in mobile applications (boats, trains, truc-

ks,etc.) or under explosive atmospheric conditions.

The date of production of the condensing unit 

is indicated on the nameplate. Ensure that the 

model and serial number information is always 

transmitted with any claim filed regarding this 

product.

Содержание Optyma Blue OP-LGHE068NTA07D

Страница 1: ...TA07D 114X8060 OP LGHE215NTA07D 114X8048 OP LGHE271NTA07D 114X8061 OP MGZE038MTA07G R404A R507 R134a 114X8062 OP MGZE048MTA07D 114X8063 OP MGZE060MTA07D 114X8064 OP MGZE086MTA07D 114X8065 OP MGZE108MT...

Страница 2: ...temperature C MGZE MTZ MBP Models R134a SH10K Wiring Diagram WD1 MGZE MTZ MBP Models R404A 507 SH10K 15 25 20 35 30 45 40 50 55 35 30 25 20 15 10 5 0 5 40 45 15 25 20 35 30 45 40 50 55 25 20 15 10 5 0...

Страница 3: ...3P 50Hz D 50Hz Voltage range 3 Phases 342V 440V G 220V 240V 1P 50 Hz Compressor 230V 1P 50Hz Fan 230V 1P 50Hz G 50Hz Voltage range 1 Phase 200V 264V D 380V 415V 3P 50 HZ Compressor 415V 3P 50Hz Fan 4...

Страница 4: ...Instructions 4 AN293820378892en 000101 Danfoss DCS CC 2019 01 For R404A models HP bar LP bar MBP 28 8 LBP 28 3 Factory setting...

Страница 5: ...rosive flammable atmosphere 3 Safety measures prior to assembly All installation and servicing is to be performed by qualified personnel in compliance with all pertinent practices and safety procedure...

Страница 6: ...r than to the Schrader connec tion This recommendation allows avoiding excessive pressure losses Moisture level At the time of commissioning system moisture content may be as high as 100 ppm During op...

Страница 7: ...filter dryer expansion valve etc refrigerant charge Low refrigerant charge the correct refrige rant charge is given by the liquid sight glass indication the condenser delta T in relation to the refrig...

Страница 8: ...cut the compressor shell and adjacent tubing release of liquid refrigerant can cause flash freezing on exposed skin Even though fans are fitted with safety guard it is recommended not to work on conde...

Отзывы: