19-27 Index maximum velocity
Range:
Function:
100
ERPM
[1...999.999 ERPM]
This setting is relevant during positioning with the current tra-
jectory index.
NB!
This parameter is automatically updated depending on INDEX NUMBER. The setting
should never exceed a value that is approx. 5% lower than the value calculated in
P32-80.
19-28 Index trajectory type
Option:
Function:
[0]
*
absolute
[1]
Relative
[2]
Touch probe positive
[3]
Touch probe negative
The function of this parameter setting is described under TARGET POSITION.
NB!
This parameter is automatically updated depending on INDEX NUMBER.
19-29 Parameter save
Option:
Function:
[0]
*
No action
This parameter automatically resets to “0” when the data is
successfully stored.
[1]
SAVE EEPROM
Trajectory data is not automatically stored in EEPROM and will
thus not automatically be available after power-down and pow-
er-up. To permanently store changes made to trajectory this
parameter must be set to “1”.
19-30 Main screen setup save
Option:
Function:
[0]
*
No action
Mains screen setup is not automatically stored in EEPROM and
will thus not automatically be available after power-down and
power-up.
This parameter automatically resets to “0” when the data is
successfully stored.
[1]
SAVE EEPROM
To permanently store changes made to the main screen setup
this parameter must be set to “1”.
MCO351 Positioning Controller
4. Programming
MG.33.R1.02 - VLT
®
is a registered Danfoss trademark
25
4