MCD500 PCB Replacement 

 

MCD 500 PCB Replacement - Instructions 

 MI.17.F1.02 

VLT

®

 is a registered Danfoss trademark 

Page 5/5 

Unplug the header connector from the main 
control PCB and set aside. 

Remove 7 x Torx screws. Replace the LCP and main 
control PCB assembly. Replace the 7 x Torx screws. 

Replace the header connector. 

 

Replace the model board, check that the header 
connector pins line up with the main control PCB 
below. 

Replace the PCBs, plug in the looms, and replace 
the LCP, top cover and terminal plugs. Take note 
of the thermistor wiring (grey/red) to the right, 
and fan wiring (black/red) to the left of the board.

 

Replace the 4 x Torx screws to secure the top 
plastic and replace the top cover and terminal plugs.

 