Code (hex)
Meaning
0
No fault
1000
General fault
2130
Short Circuit
2213
Overcurr. during startup
2240
Short to earth
2310
Continuous overcurrent
2311
Current inside the device, No. 1
3100
Mains voltage
3130
Phase failure
3210
Overvoltage inside the device
3220
Undervoltage inside the device
3300
Output voltage
4210
Exceed device temperature
4310
Excess frequency converter temperature
5110
Low voltage power supply
5112
+24 V Power supply
5210
Measurement circuit
6100
Internal software fault
7110
Brake chopper
8100
Communication
8302
Torque limiting
Table 7.25 Byte 0 and 1
0
No errors
1
Error active
Table 7.26 Byte 2
Bit0
1, Alarmword 1 has an active Alarm (
16-90 Alarm Word
)
Bit1
1, Alarmword 2 has an active Alarm (
16-91 Alarm Word
2
)
Bit2
0, Reserved
Bit3
1, Warningword 1 has an active Warning (P 16-92)
Bit4
1, Warningword 2 has an active Warning (P 16-93)
Bit5-15 0, Reserved
Table 7.27 Byte 3
Reserved
Table 7.28 Byte 4 to byte 7
Communication Profile Area
MCA 124 EtherCAT Operating Instruction
MG92A302 - VLT
®
is a registered Danfoss trademark
31
7