8

100

-100

VALVE STEP

VALVE STEP

-10.0

-0.1

.01

10.0

ERROR (IN.)

OUTPUT (%)

ERROR DEADBAND ADJUSTMENT

ADJUST

ADJUST

HIDDEN ACCESS

STATUS DISPLAY DIAGRAM

Control Nulled (Within Deadband)

Valve Drive Less Than 25%

Valve Drive 25% to 50%

Valve Drive 50% to 75%

Valve Drive 75% to 100%

Valve Full On

Control Loop Indicators Active in Auto or Manual Mode

1960

OPERATOR CONSOLE SETUP

The console has two setup values which may be adjusted to

enhance  machine  operation.  The  first,  sensitivity,  affects

control responsiveness. See the Sensitivity, Error Deadband

And Valve Step Diagram.The second, display offset, is a

convenient way to reference the machine position display to

the work surface.

Sensitivity is adjusted by actuating the toggle switch with the

sensitivity switch pushed in. Display offset is changed by

actuating  the  toggle  switch  with  the  display  offset  switch

pushed in. A zero display value may be obtained by pressing

the  null  setpoint  key  while  holding  the  display  offset  key

down.

The control console may be set up for many different types

of machines and to accomodate various operating conditions

which change infrequently. These are selected by accessing

the control parameters with a switch sequence on the operator

panel, then selecting the desired configuration variable and

its desired value. See Table A. Hidden Access Configuration

Variables for a list of variables which are available.

There are three levels of hidden access which are available:

factory, dealer and foreman. The assignment of configuration

variables to a particular hidden access level is accomplished

with the special configuration section of the ordering code.

Consult Danfoss.

 The foreman level is accessed with the sensitivity switch and

null switch in sequence. Dealer access variables are available

with a second switch sequence from the foreman  access

mode.  Access  to  the  dealer  level  parameters  also  gives

access  to  all  foreman  level  parameters.  Variables

designated as factory access are factory-set and cannot be

changed in the field.

Error deadband and valve step are adjustments which are

provided  which  would  normally  be  assigned  to  foreman

access. Error deadband is the amount of sensor travel which

can occur without valve drive. The foreman should set the

relevant error deadband configuration variable (slope, wand

or ultrasonic) depending on which type of sensor he is using

(a pendulum for slope, a wand or ultrasonic for grade) and

leave the other two at their factory setting. Valve step ad

j

ust

is the amount of step valve drive provided with a sensed error

just outside the error deadband. When adjusting valve step,

the setting/message display shows raise or lower cylinder

speed if pushing the setpoint/actual switch. See the Sensitivity,

Error Deadband And Valve Step Diagram.

Variables not used by the particular KGS ordered will not be

displayed when scrolling through the hidden access list.

100

OUTPUT (%)

40

ERROR
DEADBAND

10.0

ERROR (IN.)

-40

-10.0

-100

VALVE STEP ADJUSTMENT

ERROR
DEADBAND

ADJUST

ADJUST

1849

1850

1848

SENSITIVITY, ERROR DEADBAND AND VALVE STEP DIAGRAM

S=10.0

S=1.0

VALVE STEP

10.0

0.2

-0.2

VALVE STEP

-10.0

ERROR (IN.)

-100

S=10.0

S=1.0

100

OUTPUT (%)

E R R O R
DEADBAND

E R R O R
DEADBAND

SENSITIVITY ADJUSTMENT

ADJUST

ADJUST

Содержание KGS

Страница 1: ...es or proportional solenoid valves Fault recognition with diagnostics Full electrical and environmental protection Fewerelectricalaccessoriesandreducedmachine wiring possible SYSTEM CONFIGURATION The...

Страница 2: ...uto mode from manual mode the prior setpoint is not saved but must be reset by the operator The motion interlocks are disabled with this option Controller Outputs 5 Solenoid valve or servovalve high s...

Страница 3: ...l current CAN CONNECTION Two wire shielded cable Consult Danfoss ENVIRONMENTAL OPERATING TEMPERATURE 40 to 70 C 40 to 158 F MOISTURE Protected against 95 relative humidity Packaged to withstand high p...

Страница 4: ...4 DIMENSIONS Dimensions of the KGS in Millimeters Inches 1961...

Страница 5: ...s The mating connector assembly for the KGS console must be ordered separately The Danfoss part number is K18169 which is composed of 28 pins 8 seal plugs 1 connector and 3 connector keys 9 8 7 6 5 4...

Страница 6: ...rmined by built in software and by instructions received from the operator s use of switches Continuous operating information is provided to the operator with displays which are continuously monitorin...

Страница 7: ...effective reference point Both setpoint and actual displays are changed simultaneously Holding this switch and pushing the null setpoint switch will alternately zero the display offset or zero the dis...

Страница 8: ...variables to a particular hidden access level is accomplished with the special configuration section of the ordering code Consult Danfoss The foreman level is accessed with the sensitivity switch and...

Страница 9: ...m Interlock travel speed Machine speed to turn control 0 0 to 20 0 ft min or 0 to 7 0m min 10 0 ft min Dealer on or off Switch interlock delay Time delay after forward motion 0 0 to 10 0 sec 10 0 sec...

Страница 10: ...repair or evaluation include a description of the problem and what work you believe needs to be done along with your name address and telephone number RETURN TO Danfoss US Company Return Goods Departm...

Отзывы: