Danfoss KGS Скачать руководство пользователя страница 5

5

ROAD SENTRY SYSTEM CONFIGURATION DIAGRAM

1957

KGS

CONTROL

CONSOLE

KGS

CONTROL

CONSOLE

KUS

ULTRASONIC

GRADE SENSOR

MOTION

INPUT

CONTROL

VALVE

MCX104A

SLOPE

SENSOR

CONTROL

VALVE

MCX104A

OPTIONAL

SENSOR

KUS

ULTRASONIC

GRADE SENSOR

MCX103A

WAND

GRADE

SENSOR

MCX103A

WAND

GRADE

SENSOR

ELECTRICAL CONNECTION

See the Connector Diagram. A 28-pin ITT Cannon connector provides all input and output to the KGS Controller per the table

below. See the Road Sentry System Configuration Diagram for a pictorial view of the system level connections.

The mating connector assembly for the KGS console must be ordered separately. The Danfoss part number is

K18169, which is composed of 28 pins, 8 seal plugs, 1 connector and 3 connector keys.

9

8

7

6

5

4

3

2

1

19

18

17

16

15

14

13

12

11

10

28

27

26

25

24

23

22

21

20

1843

Pin Orientation Shown is for the Device, not the Mating, Connector.

CONNECTOR DIAGRAM

P i n Function

P i n Function

P i n Function

1 B

10 Ground

20 N/C

2 Valve raise

11 Ground

21 N/C

3 Valve lower

12 Ground

22 Sensor power

4 PPU/travel

13 Ground

23 Sensor power

5 Analog in 0

14 Ground

24 Sensor power

6 Analog in 1

15 Ground

25 CAN address 0

7 CAN shield

16 Ground

26 CAN address 1

8 CAN low

17 Ground

27 CAN address 2

9 CAN high

18 Ground

28 CAN address 3

19 Ground

Содержание KGS

Страница 1: ...es or proportional solenoid valves Fault recognition with diagnostics Full electrical and environmental protection Fewerelectricalaccessoriesandreducedmachine wiring possible SYSTEM CONFIGURATION The...

Страница 2: ...uto mode from manual mode the prior setpoint is not saved but must be reset by the operator The motion interlocks are disabled with this option Controller Outputs 5 Solenoid valve or servovalve high s...

Страница 3: ...l current CAN CONNECTION Two wire shielded cable Consult Danfoss ENVIRONMENTAL OPERATING TEMPERATURE 40 to 70 C 40 to 158 F MOISTURE Protected against 95 relative humidity Packaged to withstand high p...

Страница 4: ...4 DIMENSIONS Dimensions of the KGS in Millimeters Inches 1961...

Страница 5: ...s The mating connector assembly for the KGS console must be ordered separately The Danfoss part number is K18169 which is composed of 28 pins 8 seal plugs 1 connector and 3 connector keys 9 8 7 6 5 4...

Страница 6: ...rmined by built in software and by instructions received from the operator s use of switches Continuous operating information is provided to the operator with displays which are continuously monitorin...

Страница 7: ...effective reference point Both setpoint and actual displays are changed simultaneously Holding this switch and pushing the null setpoint switch will alternately zero the display offset or zero the dis...

Страница 8: ...variables to a particular hidden access level is accomplished with the special configuration section of the ordering code Consult Danfoss The foreman level is accessed with the sensitivity switch and...

Страница 9: ...m Interlock travel speed Machine speed to turn control 0 0 to 20 0 ft min or 0 to 7 0m min 10 0 ft min Dealer on or off Switch interlock delay Time delay after forward motion 0 0 to 10 0 sec 10 0 sec...

Страница 10: ...repair or evaluation include a description of the problem and what work you believe needs to be done along with your name address and telephone number RETURN TO Danfoss US Company Return Goods Departm...